5
N777-C Instrument's Front Panel Display
CAUTION
98
The following trigger configuration modes are available:
1
Disabled - select this mode if you do not want to use triggering. In this
case input and output connectors are disabled.
2
Default - select this mode if you want to enable the trigger connectors.
In this case input and output connectors are active.
3
Passthrough - select this mode if you want an input trigger to
automatically generate an output trigger. This allows you to trigger
another instrument almost simultaneously.
How to Use Input Triggering
You can configure your N777-C Tunable Laser instrument to perform
certain tasks when you apply a trigger to the Input Trigger Connector.
A maximum of 5 V can be applied as an external voltage to the Input
Trigger connector.
Do not apply an external voltage to these connectors.
To set your instrument's Input Trigger Configuration:
1
From the Control Instrument window, click Trigger VIEW tab.
2
Use the menu to select the Input Trigger. The following input trigger
options are available:
Ignore, input triggers are ignored.
Next Step, an input trigger will cause the next step of a stepped
sweep to be performed.
Run Sweep, an input trigger will start a single sweep cycle.
Keysight N777-C Series Tunable Laser Family User's Guide