German Light Products®
sACN
To configure the fixture to receive DMX control data via sACN, open the menus in the
fixture's control panel and make the following settings:
In the first menu (root menu), give a suitable DMX address to the fixture.
In the Protocol Setup  Protocol Type menu, set the control protocol to sACN.
Give all fixtures their own unique IP addresses. To do this, you can either:
● set fixtures to generate their own IP addresses by choosing the ranges 2.x.x.x or
10.x.x.x (Art-Net specification),
● set fixtures to acquire IP addresses automatically by DHCP, or
● assign IP addresses manually by entering individual IP addresses and Subnet mask.
Select an sACN universe from 00001 to 63999.
These settings will not be affected if you apply a Load Default Settings command in the
fixture's control panel, but they will be returned to factory defaults if you apply a Load
Factory Backup command in the fixture's control panel.