Configuration - Emerson Rosemount 2555 Quick Start Manual

Solids level switches capacitance probe

Advertisement

Quick Start Guide
4

Configuration

4.1
User interface
Figure 4-1: Features of the User Interface
1 1 2
Table 4-1: LEDs
Green
Yellow
Red
4.2
Powering up the first time (calibration)
Calibration automatically starts when the Rosemount 2555 is powered up
for the first time. If the level switch is powered off and then on again, this
calibration procedure is not repeated when starting up.
Prerequisites
The level switch must be correctly mounted and wired.
The level of the solids material must be below the probe.
Procedure
1.
20
CAL
MENU
Display
TEST
3 4 5
6 7 8
Relay is energized
Relay is de-energized
Maintenance (flashing) or error (not flashing)
Ensure the level of the solids material is not covering the probe.
LED
October 2020
Quick Start Guide