Connecting to the MPI Control Panel

To connect the 4G/LTE module to the control panel, proceed as follows:
1.
Connect the module's PWR/IO and USB connectors (F and G) to the
MPI Control Panel using the included cables.
Caution!
Insert the plugs into the PWR/IO connectors very gently; do
not apply any pressure if the plugs don't enter immediately. If
you do apply pressure, you will bend the pins in the connectors.
Make sure to align the chamfered corners of plug and
connector correctly:
2.
Clip the ferrite bead over the USB cable (F). Position it as close as possible
to the USB port on the control panel.
4.2.6

Installing the SMA Isolators on the MPI Cabinet