Network Connection (Ethernet); Connecting To The Network; Securing The Network - Honeywell MAXPRO MPIP2000U Series Installation And Setup Manual

Integrated security systems
Table of Contents

Advertisement

Installation and Setup Guide
You can bypass the tamper switches by fitting a jumper on the tamper inputs
on the control panel.
Caution!
Bypassing tamper inputs may invalidate compliance with local
regulations.
UL
The cabinet wall tamper is optional for UL/ULC installations.
3.7

Network Connection (Ethernet)

3.7.1

Connecting to the Network

The Ethernet connection provides the main connection to internet for alarm
signalling to the central monitoring station and communication with MAXPRO
Cloud.
Connect the main board (M on page 34) to the network that provides the
internet connection using a standard Ethernet cable. Clip both ferrite beads
over the cable. Position them as close as possible to the Ethernet connector on
the control panel.
The amber LED is illuminated when the network connection is working.
l
The green LED flashes when the system is sending or receiving data over
l
the network.
Upon first start-up, MAXPRO Cloud will automatically try and connect to the
control panel. By default, the system uses dynamic IP addressing (DHCP). If
connection should fail, you can edit the settings using the keypad and set up
the IP network manually. For details, see Connecting to MAXPRO Cloud on
page 119. You can view the network settings in MAXPRO Cloud.
3.7.2

Securing the Network

Make sure that the routers and firewalls in the network are set up correctly:
network address translation (port forwarding), firewall settings, etc. If not, the
control panel will not be able to send alarm and other information to MAXPRO
Cloud. The table below lists the port numbers and services that are required for
communication:
Port No.
Protocol
53
UDP
38
Honeywell MAXPRO Intrusion MPIP2000U/3000U Series
Function
DNS server
800-23044 Rev.  A draft_11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Maxpro mpip3000u seriesMaxpro mpip2100uMaxpro mpip3000u

Table of Contents