Honeywell MAXPRO MPIP2000U Series Installation And Setup Manual page 74

Integrated security systems
Table of Contents

Advertisement

Installation and Setup Guide
# Item
L IB2 BUS
M Request to
exit (RTE),
optional
N EXIT Reader
(Reader 2),
optional
Minimum Connections
The DCM simply needs wiring to the IB2 data bus, and the following minimum
connections:
1. Attach a Wiegand reader to the ENTRY Reader terminals.
2. Attach the door lock to the Door Strike/Lock terminals.
3. Attach a request to exit button to the RTE terminals.
4. Attach a door contact to the DSM terminals.
5. Optionally, you can connect the reader buzzer and red LED control lines
to the appropriate terminals on the DCM to give extra feedback.
Relay Jumper
A
3
2
1
NC
C
12V
NO
A: jumper in position 2–3 (default). Normal relay operation.
74
Honeywell MAXPRO Intrusion MPIP2000U/3000U Series
Terminal or
Connect to
connector
+12V
12 VDC supply terminal
0 VDC supply terminal
C
IB2 bus C
D
IB2 bus D
RTE
To request to exit button
To request to exit button [–] terminal.
Default supervision: EOLR (2K). For details and more
options, see Wiring Inputs (Zones) on page 39. Terminate
using resistors if not used.
+12V
Exit reader power input [+].
Exit reader power input [–]
D0
Exit reader data 0
D1
Exit reader data 1
T
Exit reader tamper.
Exit reader tamper [–]
B
3
2
1
NC
C
12V
NO
800-23044 Rev.  A draft_11