YY.MM.DD — the date displayed as Year.Month.Day
HH.MM.SS.ss — the time displayed as Hour.Minute.Second.Hundredths fo a second
First code — hard or soft error. The code after LIB/ERR (80 in the example) will be 80 or 40. 80
indicates a hard error, 40 indicates a soft error.
Second code — the main error code (89 in this example). See
list of error codes and recovery procedures.
Third code — the sub-code (62 in this example). See
for a list of sub-codes.
Fourth code — sub-code-specific information for factory use only
Figure 101 Support: Library logs page
.
Finding error code information on an L&TT support ticket or report
An L&TT support ticket or report contains detailed information about the device configuration, along
with errors and warnings. The support ticket and report contain the same information. The report is
easier to read, but must be generated and read on the host computer. The support ticket can be
downloaded from the device and then viewed on any computer with L&TT installed.
To generate and view a report or support ticket from L&TT:
1.
In the L&TT By Product or By Connection tab, select the device from the device list.
2.
Click the Health button on the main toolbar to generate and display a standard report. or click
the Support button on the main toolbar to display the Support screen for additional report or
support ticket options.
To download a support ticket from the device, do one of the following:
From the RMI Support: Support ticket screen, click Download.
Insert a USB flash drive into the USB port on the rear panel and then from the OCP, select Download
support ticket to USB.
182
Troubleshooting
Error
codes" on page 180 for a
Error sub-code
descriptions" on page 196