53-1004105-13 Hardware Installation Guide
Power Supply Requirements
The minimum number of power supplies needed in your system for operation and to achieve redundancy depends on
the blade and port configuration and on the AC or DC input voltage level. N is the minimum number of power supplies to
operate the configuration; N+N doubles the number of power supplies for full AC or DC input and DC output redundancy;
and N+1 adds an additional power supply for DC output redundancy in the case of a single power supply failure. Although
examples for different port and blade configurations are provided, for more information and help with determining the
actual number of power supplies for your deployment, contact your local Brocade representative.
NOTE
In the following table, HVAC and HVDC indicate voltages from the high-voltage AC and high-voltage DC power
supply.
Model Name
144 32G ports and
Brocade X6-8
QSFP ICLs
384/512 32G ports and
Brocade X6-8
QSFP ICLs
Any combination of 32G
Brocade X6-8
ports, Extension blades,
and QSFP ICLs
Fibre Channel Data Transmission Ranges
Port Speed (G)
4
8
Broadcom
Configured Ports
100–120 VAC (low line)
100–120 VAC (low line)
200–240 VAC (high line)
200–277 HVAC (high line)
240–380 HVDC
100–120 VAC (low line)
200–240 VAC (high line)
200–277 HVAC (high line)
240–380 HVDC
200–240 VAC (high line)
200–277 HVAC (high line)
240–380 VDC
100–120 VAC (low line)
200–240 VAC (high line)
200–277 HVAC (high line)
240–380 HVDC
200–240 VAC (high line)
200–277 HVAC (high line)
240–380 HVDC
Cable Size
Short Wavelength (SWL)
(Microns)
50
150m (492 ft) (OM2)
380m (1264 ft) (OM3)
400m (1312 ft) (OM4)
62.5
70m (229 ft)
9
N/A
50
50m (164 ft) (OM2)
150m (492 ft) (OM3)
190m (623 ft) (OM4)
62.5
21m (68 ft)
Input Connection
Long Wavelength
(LWL)
N/A
N/A
30 km (18.6 miles)
N/A
N/A
Minimum Power
Supplies for
Operation
2
3 (N+1)
2
4 (N+N)
1
2 (N+N)
3
Not supported
2
3 (N+1)
2
4 (N+N)
3
Not supported
2
3 (N+1)
2
4 (N+N)
Extended Long
Wavelength (ELWL)
N/A
N/A
N/A
N/A
N/A
Brocade X6-8 Director
Hardware Installation Guide
Number of Power
Supplies for
Redundancy
53-1004105-13
188

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Brocade X6-8 Director and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents