Broadcom Brocade X6-8 Director Hardware Installation Manual page 74

Table of Contents

Advertisement

53-1004105-13 Hardware Installation Guide
Table 14: Extension Blade LED Descriptions
LED Purpose
Power
Steady green
No light (LED is off)
Status
No light (LED is off)
Steady amber
Blinking amber and green.
Green
GbE port status
No light (LED is off)
Steady green
linking green
Blinking amber
FC port status
No light (LED off)
Steady green
Slow-flashing green (on 1 second,
then off 1 second)
Fast-flashing green (on 1/4 second,
then off 1/4 second)
Flickering green
Steady amber
Broadcom
Color
The blade is operational.
The blade is not powered on.
The blade is either healthy or does
not have power.
The blade is faulty or initializing.
Attention. The blade is not seated
correctly or is faulty.
The blade is operational.
The port has no incoming power or
is offline.
Port is online but has no traffic.
Port is online, with traffic lowing
through the port.
A transceiver or port has an error or
is faulty.
Port has no incoming power, or
there is no light or signal carrier
detected.
Polling is in progress.
The connected device is configured
in an offline state.
The port is online (connected to an
external device) but has no traffic.
The port is online but segmented,
indicating a loopback plug or cable
or an incompatible switch.
Port is in internal loopback
(diagnostic).
Port is online, with traffic flowing
through the port.
Port is receiving light or signal
carrier, but it is not online yet.
Status
No action is required.
Ensure that the blade is firmly
seated, with ejectors pushed in
fully to the center of the blade and
ensure that the captive screw for
each ejector is fully tightened.
Verify that the power LED is on.
Ensure that the blade is firmly
seated and check the status by
entering the
If LED remains amber, consult the
device supplier.
Pull the blade out and reseat it. If
LED continues to flash, replace the
blade.
No action required.
Verify that the power LED is on,
check the transceiver and cable.
No action is required.
No action is required.
Change the transceiver or reset the
switch from the workstation.
Verify that the power LED is on,
check the transceiver and cable.
Allow 60 seconds for polling to
complete.
Verify the status of the connected
device.
No action is required.
Verify that the correct device is
attached to the chassis.
No action is required.
No action is required.
Reset the port from the workstation
using the port
portCfgPersistentEnable
command.
Brocade X6-8 Director
Hardware Installation Guide
Recommended Action
slotShow
command.
Enable
or
53-1004105-13
74

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Brocade X6-8 Director and is the answer not in the manual?

Table of Contents