Heta SCAN-LINE SOLID C Operating And Installation Instructions

Heta SCAN-LINE SOLID C Operating And Installation Instructions

Hide thumbs Also See for SCAN-LINE SOLID C:

Advertisement

Quick Links

OPERATING AND INSTALLATION
INSTRUCTIONS
SCAN-LINE SOLID C
THE SCAN-LINE SOLID C IS EXEMPT FOR USE
IN SMOKE CONTROL AREAS WHEN BURNING DRY WOOD
ECODESIGN READY
www.heta.dk
EN
DANISH DESIGN . DANISH QUALITY . DANISH PRODUCTION
1

Advertisement

Table of Contents
loading

Summary of Contents for Heta SCAN-LINE SOLID C

  • Page 1 OPERATING AND INSTALLATION INSTRUCTIONS SCAN-LINE SOLID C THE SCAN-LINE SOLID C IS EXEMPT FOR USE IN SMOKE CONTROL AREAS WHEN BURNING DRY WOOD ECODESIGN READY www.heta.dk DANISH DESIGN . DANISH QUALITY . DANISH PRODUCTION...
  • Page 2 Signed on behalf the manufacturer of 16.11.2017 ____________________________________________________________________________________________________________________ In case of any change of the above-mentioned production type this Declaration of Performance becomes invalid. Heta A/S, Jupitervej 22, DK-7620 Lemvig, Tlf. +45 9663 0600, www.heta.dk Page 1 of 1...
  • Page 3: Table Of Contents

    The Scan-Line Solid C have been approved according to the EN 13240, NS 3058/3059 and the Scan-Line Solid C is modified so that they are also recommended as exempt for use within smoke control areas (SCA) throughout the UK (see clean air act Appen- dix A).
  • Page 4: Before Installation

    It is important that upon receipt check your Heta product completely and report any damage or defects to your dealer. The packaging must be disposed of as follows: Wood is untreated and able to burn in the stove.
  • Page 5 Solid C High Concrete element 1 x 0023-2507 Concrete element 1 x 0023-2508 1 x 0023-2509 1 x 0023-2509 Heat shield 1 x 1022-0087 Heat shield 2 x 1022-0090 2 x 1022-0090 1 x 1022-0091 1 x 1022-0091 1 x 1022-0094 External air from behind 1 x 0032-0027...
  • Page 6: Accessory Parts

    Accessory Parts Akkumulation External air from below, complete 1511-0033 1 x 0023-0237 - 1011-0275 1511-0032 - 2 x 0023-0237 - 1011-0276 3 x 0023-0237 4 x 0008-1720 3,9x14 4 x 0023-0237 5 x 0008-2301 M4x8 (Solid C High) Solid C Solid High External air from behind (1324 mm) External air from behind (1824 mm)
  • Page 7: Operating Instructions

    Refueling of your stove should be done while there is still a good layer of embers. Distribute The Scan-Line Solid C stoves are designed and the embers with the majority of them to the front. tested to burn extremely cleanly with very little...
  • Page 8: Reduced Burning

    come from the tree, when it is becomes glowing charcoal. If you are looking for less heat out-put, achieve this by fueling with smaller volumes of wood and a lower operating air. You may not completely close the operating air during firing. Be aware that the stove will naturally soot if the operating air is too low.
  • Page 9: Draft Conditions In The Chimney

    • Poorly placed chimney for the surroundings, timal combustion and the highest possible ef- for ex. the ridge and trees may cause ficiency. Heta wood stoves are constructed so turbulence. that it itself provides an optimal blend of com- bustion air. This provides a high efficiency/heat, Good draft occurs when: clean glass and low environmental impact.
  • Page 10: Fuel

    1.10 Fuel almost the same heating value per kg, which is about 5.27 kW/hour for absolute dry wood. Your new stove is EN approved for firing with Wood with a moistness of 18% has a efficiency wood fuel. You must therefore only burn clean, of about 4.18 kW / hour per kg, and one litre dry wood in your stove.
  • Page 11: Troubleshooting

    1.13 Troubleshooting table - applies to all stove types Fault Cause Troubleshooting Solution Inadequate chimney draft. Lighting problems. When the You can test using a lighter whether Improve the chimney. The chimney only has stove is cold, smoke seeps flame is drawn into the combustion sufficient draft when it is hot.
  • Page 12: Maintenance

    1.14 Maintenance 1.15 Cleaning the glass Incorrect firing, for example using wet wood, The surface of the stove is treated with a heat- can result in the viewing window becoming resistant paint. The stove should be cleaned covered in soot. This soot can be easily and with a damp cloth.
  • Page 13: Cleaning/Replacing Bricks After Chimney Sweeping

    1.17 Cleaning after sweeping or before replacing vermiculite stones Note: it may be necessary to clean/vaccum the holes and air ducts behind the rear stone Removal sequence of stones. Replace in reverse order. Starting with Fig. 8.
  • Page 14: Stove Data Table En 13240

    + 138 kg 8 x 0023-0237 + 184 kg 1.19 Guarantee Heta wood stoves, subjected to a strict quality Should you have cause to make a complaint, control during production and before delivery to please quote our invoice no. the dealer.
  • Page 15 1.20 Reservedele 34 - 35 - - 36 33 - 11 - - 37 32 - 31 - - 30 10 - - 22 12 - 13 - 14 - 15 - 16 - - 23 x 4 - 24 x 2 - 18 - 25 x 2 - 26 x2...
  • Page 16 Pos. No. Name Qty. Pos. No. Name Qty. 0023-0213 Top Back stone, left 21 1513-0123* Closing System 22 1505-0084** Left-hinged door 0023-0215 Left baffle 0023-0214 Right baffle 23 5013-0011 Rep. set glass clips sidelight 0023-0212 Lower back stone, left 24 0021-0066 Side Glass, large 0023-0211 Top back stone, right 25 0023-3010...
  • Page 17: Installation Instructions

    The frame is made of fibreglass-reinforced concrete elements, making it highly resistant to thermal stress. The concrete elements are cast, which means there may therefore be variations in surface and structure. If the concrete elements are damaged, use the repair mortar provided. The frame surfaces can be painted without priming.
  • Page 18: Installation Instructions

    We recommend that you let a 2.2 Floor professional Heta dealer install the stove. Alter- You must ensure that the floor can support the natively, you can ask the local chimney sweep weight of the stove and a top-mounted steel before installation.
  • Page 19: Combustion Air

    In this respect, the fol- must be sealed with fireproof material and / or lowing requirements must be met: beading. Heta A/S stresses that it is of utmost importance that this is done correctly with very • Only approved materials may be used from tight joints.
  • Page 20: Clearances For Installation En 13 240

    2.5 Clearances for installation EN 13 240 The Building materials that are used in safety test and shown in illustrations on this page, has a thermal conductivity of max. (= <0.36 W (m * K) Solid C and Solid C high 1.
  • Page 21: Parts

    2.7 Fitting the flue collar 2.8 Mounting of accumulation Solid C and Solid C high (Accessory Parts) The flue collar is bolted to the stove from inside the fire chamber with, 4 x M6x10 0008-1117. Installation of the stove Solid C and Solid C high 3 min.
  • Page 22 2 x 1013-1006 ≈ 3 ≈ 3...
  • Page 23 Scan-Line Solid C 13 x M6 x 25 0008x1807 13 x M6 x 8 0008-0035 BETJENINGS- OG OPSTILLINGSVEJLEDNING SCAN-LINE SOLID C www.heta.dk DANSK DESIGN . DANSK KVALITET . DANSK PRODUKTION...
  • Page 24 Scan-Line Solid C high 13 x 13 x M6 x 25 M6 x 8 0008x1807 0008-0035...
  • Page 25: Rear Flue Outlet

    2.9 Rear flue outlet (Accessory 5032-0082 Solid C and 5032-0092 Solid High)
  • Page 26: Connecting External Air Supply From Below

    3. Connecting external air supply from below 5 x M4x8...
  • Page 27: Connecting External Air Supply From Behind

    4. Connecting external air supply from behind...
  • Page 28 5. Appendix A The Clean Air Act 1993 and Smoke Control Areas. Under the Clean Air Act local authorities may gulatory Reform (Scotland) Act 2014. In Wales declare the whole or part of the district of the and Northern Ireland these are authorized by authority to be a smoke control area.