Heta Inspire 40H Operating And Installation Instructions

Heta Inspire 40H Operating And Installation Instructions

Hide thumbs Also See for Inspire 40H:

Advertisement

oPeratinG anD installation
instrUCtions
insPire 40-40h / 45-45h / 55-55h stove
is exempt for use in smoke control areas when burning dry wood
www.heta.dk
en
Danish DesiGn . Danish QUality . Danish ProDUCtion
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Inspire 40H and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Heta Inspire 40H

  • Page 1 40-40h / 45-45h / 55-55h stove is exempt for use in smoke control areas when burning dry wood www.heta.dk Danish DesiGn . Danish QUality . Danish ProDUCtion...
  • Page 2: Declaration Of Performance

    ____________________________________ Lemvig 18-08-2016. Lars Kirk HOD _________________________________________________________________________________________ In case of any change of the above-mentioned production type this Declaration of Performance becomes invalid . Heta A/S, Jupitervej 22, DK - 7620 Lemvig, Tlf.: +45 96630600, www.heta.dk Page 1 of 1...
  • Page 3 ____________________________________ Lemvig 18-08-2016. Lars Kirk HOD _________________________________________________________________________________________ In case of any change of the above-mentioned production type this Declaration of Performance becomes invalid . Heta A/S, Jupitervej 22, DK - 7620 Lemvig, Tlf.: +45 96630600, www.heta.dk Page 1 of 1...
  • Page 4: Declaration Of Performance

    ____________________________________ Lemvig 18-08-2016. Lars Kirk HOD _________________________________________________________________________________________ In case of any change of the above-mentioned production type this Declaration of Performance becomes invalid . Heta A/S, Jupitervej 22, DK - 7620 Lemvig, Tlf.: +45 96630600, www.heta.dk Page 1 of 1...
  • Page 5: Table Of Contents

    Congratulations on your new wood stove, we are confident that you will be more than satisfied with your new Heta stove. Especially if you follow the following advice and instructions. Inspire 40 wood stove is approved according to EN 13240, NS 3058 and 3059. These...
  • Page 6: Before Installation

    It is important that upon receipt check your Heta product completely and report any damage or defects to your dealer. The packaging must be disposed of as follows: Wood is untreated and able to burn in the stove.
  • Page 7 Ash pan handle Heta glove 1020-0001 Data plate 2 x M8x25 0008-0206 8150-0000-DK 2 x M6x30 0008-1118 DOP-Inspire 40 Indsats-2215-2016 Heta A/S Jupitervej 22 7620 Lemvig Denmark Produktions år: 2016 2 x Washer 0008-0501 DS/EN 13229/A2:2004/NS 3058/3059 Produkt beskrivelse Serie nr:...
  • Page 8: Operating Instructions

    (after about ten minutes) closed door 1.2 first firing and regulate the air into operating position. We Heta wood stoves are, treated with a heat-resi- recommend, all of the first fuel is burned with stant coating, which hardens at a temperature the combustion air fully open in the operating of about 250°...
  • Page 9: Emptying The Ash

    may be necessary to use the start-up air and the ashtray, see Fig. 6. It is advantageous to possibly have the door ajar. leave a layer of ash in the bottom of the combu- stion chamber on top of the grate as insulation. The wood will then ignite within a very short time For emptying the ash pan - use the supplied (Typically 1 to 3 minutes).
  • Page 10: Draft Conditions In The Chimney

    Good draft will allow the stove to achieve op- reduced draft can occur when: timal combustion and the highest possible ef- ficiency. Heta wood stoves are constructed so • The temperature difference is too small that it itself provides an optimal blend of com- between smoke gasses and outdoor bustion air.
  • Page 11: Operating Problems

    chimney. Similarly, you must not fire your stove heating oil contains about 10 kW / hour. with refuse, painted wood, pressure-impregna- release ted wood or chipboard, as these materials can emit poisonous fumes and smoke. At combustion 1000 litres of heating oil forms 3.171 tons CO .
  • Page 12: Troubleshooting

    1.13 troubleshooting table Fault Cause Troubleshooting Solution Inadequate chimney draft. You can test using a lighter whether Improve the chimney. Lighting problems. When the The chimney only has stove is cold, smoke seeps flame is drawn into the combustion sufficient draft when it is hot. into the room.
  • Page 13: Maintenance

    1.14 Maintenance 1.15 Cleaning the glass Incorrect firing, for example using wet wood, The surface of the stove is treated with a heat- can result in the viewing window becoming resistant paint. The stove should be cleaned covered in soot. This soot can be easily and with a damp cloth.
  • Page 14: Cleaning/Replacing Bicks After Chimney Sweeping

    1.17 Cleaning after sweeping or before replacing vermiculite stones Note: it may be necessary to clean/vaccum the holes and air ducts behind the rear stone Order of removing Fire bricks. Inspire 55-55H Inspire 40-40H + 45-45H Replace in reverse order. Starting with Fig. 6.
  • Page 15: Parts Inspire 40-40H

    1.18 Parts inspire 40-40h stove - 5 x2 2 x4 13 - 14 - 15 - - 16 Pos. No. Name Qty. Pos. No. Name Qty. 1 5013-0008 Handle 0030-0201 Shaking grate, Ø195 mm 1 2 5013-0009 Set of glass clips 0015-2013 Shaking grate handle 3 0021-0053...
  • Page 16: Parts Inspire 45-45H

    1.19 Parts inspire 45-45h stove - 5 x2 -2 x4 13 - - 10 15 - - 17 - 21 18 - 16 - - 11 19 - - 20 - Pos. No. Name Qty. Pos. No. Name Qty. 1 5013-0008 Handle 0030-0201 Shaking grate, Ø195 mm 1...
  • Page 17: Parts Inspire 55-55H

    1.20 Parts inspire 55-55h stove - 5 x2 -2 x4 13 - - 10 15 - 18 - - 17 - 21 16 - 19 - - 20 - - 11 Pos. No. Name Qty. Pos. No. Name Qty. 1 5013-0008 Handle 0030-0201 Shaking grate, Ø195 mm 1...
  • Page 18: Stove Data Table En 13240

    The nominal output is the output to which the stove has been tested. The test was carried out with the combustion air 65%. 1.21 Guarantee Heta wood stoves, subjected to a strict quality Should you have cause to make a complaint, control during production and before delivery to please quote our invoice no.
  • Page 19: Installation Instructions

    installation instructions Contents Installation instructions ..............20 Distance requirements ..............20 Floor ....................20 Chimney connection ................. 20 Combustion air and ventilation ............21 Stovedrawings/measurments ............22 Clearances for installation - EN 13240 40-45-55 ......23 Clearances for installation - EN 13240 40H-45H-55H .......24 Mounting the flue collar ..............
  • Page 20: Installation Instructions

    We recommend that you let a professional Heta dealer install the stove. Alter- In front of the fireplace insert, the substrate natively, you can ask the local chimney sweep must consist of non-combustible material, for before installation.
  • Page 21: Combustion Air And Ventilation

    / or 2010) especially when installing in newer build beading. Heta A/S stresses that it is of utmost properties when the stove is not going to be in- importance that this is done correctly with very stalled to an outside air supply.
  • Page 22: Stovedrawings/Measurments

    2.5 stovedrawings/measurments Type Inspire 40 Inspire 40H Inspire 45 Inspire 45H Inspire 55 Inspire 55H F: Measurements to openings...
  • Page 23: Clearances For Installation - En 13240 40-45-55

    2.6 Clearances for installation en 13 240 - inspire 40-45-55 Not combustible material Combustible material - Insulated flue Min. The dimensions are the minimum dimensions, unless otherwise stated. Snit A-A Snit B-B Clearances Srove Distance to flamable materials Minimum dimensions i rear the at the door bot-...
  • Page 24: Clearances For Installation - En 13240 40H-45H-55H

    2.7 Clearances for installation en 13 240 - inspire 40h-45h-55h Not combustible material Combustible material - Insulated flue Min. The dimensions are the minimum dimensions, unless otherwise stated. Snit A-A Snit B-B Clearances Stove Distance to flamable materials Minimum rear the...
  • Page 25: Mounting The Flue Collar

    2.8 Mounting of the flue collar 4025-0007- 2.9 Changing to a back outlet DETAIL D SCALE 1 : 1.5 4012-0004- 4025-0007-...
  • Page 26: Data Plate

    3. Data Plate Inspire 40-40H Inspire 45-45H Note your own number here 8050-0000-EN 8052-0000-EN DOP-Inspire 40 -1858-2016 DOP-Inspire 40 -1987-2016 Heta A/S Jupitervej 22 Heta A/S Jupitervej 22 7620 Lemvig Denmark 7620 Lemvig Denmark 2013 Production år: 2013 Production år:...
  • Page 27 4. appendix a The Clean Air Act 1993 and Smoke Control Northern Ireland. Therefore it is a requirement Areas Under the Clean Air Act local authorities that fuels burnt or obtained for use in smoke may declare the whole or part of the district of control areas have been ”authorised”...

This manual is also suitable for:

Inspire 40Inspire 45hInspire 55Inspire 55hInspire 45

Table of Contents