Heta SCAN-LINE CLASSIC RECESSED Operating And Installation Instructions

Heta SCAN-LINE CLASSIC RECESSED Operating And Installation Instructions

Advertisement

Quick Links

OPERATING AND INSTALLATION
INSTRUCTIONS
SCAN-LINE CLASSIC
RECESSED
www.heta.dk
EN
DANISH DESIGN . DANISH QUALITY . DANISH PRODUCTION
1

Advertisement

Table of Contents
loading

Summary of Contents for Heta SCAN-LINE CLASSIC RECESSED

  • Page 1 OPERATING AND INSTALLATION INSTRUCTIONS SCAN-LINE CLASSIC RECESSED www.heta.dk DANISH DESIGN . DANISH QUALITY . DANISH PRODUCTION...
  • Page 2 Congratulations on your new wood stove insert, we are confident that you will be more than satis- fied with your new Heta stove. Especially if you follow the following advice and instructions. The Classic Insert stove is approved according to EN 13229. These approvals, means that the wood stove insert meets a variety of specifications and requirements, ensuring it is made of quality mate-...
  • Page 3: Installation Instructions

    INSTALLATION INSTRUCTIONS of the non-combustible surface must follow the Safety clearances applicable national and local regulations. Pro- Stoves must always be installed in line with nati- tecting your floor from embers that may fall out onal and, if applicable, local regulations. It is im- of the oven.
  • Page 4 Draft conditions Reduced draft can occur when: • The difference in temperature is too small Poor draft may result in smoke being emitted from the stove when the door is opened. The – due to insufficient chimney insulation, for minimum chimney draft to ensure satisfacto- example.
  • Page 5 Heating value in wood The use of lighter fluid, oils or any liquid fuels is strictly forbid- You have to use about 2.4 kg normal wood to den from use in a wood stove. replace one litre of heating oil. All woods have almost the same heating value per kg, which Fully open the combustion air and leave the is about 5.27 kW/hour for absolute dry wood.
  • Page 6: Reduced Burning

    Reduced burning will prevent oxygen from being drawn into the stove, and the viewing window and other parts The stove is well suited to intermittent use. If will become covered with soot. If this situation is you wish to operate the stove with reduced out- combined with firing with wet wood, the build-up put, simply insert smaller volumes of wood at of soot can become so thick and sticky that the...
  • Page 7: Maintenance

    Guarantee Heta wood stoves, subjected to a strict quality - Damage caused by improper use. control during production and before delivery to - Transportation costs for warranty repair.
  • Page 8 Clearances for installation EN 13 229 The Building materials that are used in safety test and shown in illustrations on this page, has a thermal conductivity of max. (= <0.36 W (m * K) insulated flue connection Not combustible material 12,5 (=<0,36 W/(m*K) 600 cm 600 cm...