Congratulations on your new wood stove insert, we are confident that you will be more than satis- fied with your new Heta stove. Especially if you follow the following advice and instructions. The Scan-Line 95 and 100 series are approved according to EN 13240, NS 3058 and NS 3059.
installation instrUCtions safety clearances the chimney connection Stoves must always be installed in line with nati- The chimney opening must follow national and onal and, if applicable, local regulations. It is im- local regulations. However, the area of the ope- portant to abide by local regulations regarding ning should never be less than 175 cm , which...
The chimney draft is generated by the difference • The chimney is too low and sheltered. between the high temperature of the chimney • The chimney contains false air. and the low temperature of the fresh air. The • The chimney and flue gas pipe are blocked. length and insulation of the chimney, wind and • The house is too airtight (i.e.
regulate the air into operating position. We re- energy source, you save the environment about commend, all of the first fuel is burned with the 1.3 kg CO every time you have used 1 kg nor- combustion air fully open in the operating po- mal wood.
supply must never be shut off completely du- of soot can become so thick and sticky that the ring firing. It is important to keep a good bed of sealing rope can, for example, become detached embers. Gentle heat is released when the fire when the door is opened the next day.
Page 7
Cleaning after sweeping or before replacing vermiculite stones Note: it may be necessary to clean/vaccum the holes and air ducts behind the rear stone Removal sequence of stones. Scan-Line 100 Replace in reverse order. Starting with Fig. 5. rear stone Scan-Line 95 The rear stone on Scan-Line 100 is divided into two.
external fresh air - accessory Pedestal Models Models without pedestal Scan-Line 95 fast pedestal Scan-Line 95 Scan-Line 95 rotating pedestal Scan-Line 95R Scan-Line 100 fast pedestal Scan-Line 100 Scan-Line 100 rotating pedestal Scan-Line 100R Scan-Line 100R fast pedestal Scan-Line 100R rotating pedestal - 1511-0028 fast pedestal Behind...
Page 9
Connecting external fresh air supply from below Remove the vermiculite in the combustion chamber. See on page 7. 0032-0015 - accessory 1515-0013 - Check that the air controller moves freely. Replace the vermiculite. See page 7.
Connecting external air supply from behind 1511-0028 - Possibly leakage around the coupling spigot can be sealed with heat resistant silicone or fire rope. operational problems The chimney must be swept at least once a year, and an increased risk of soot deposits in the we recommend the use of a NACS (national as- chimney.
Page 11
Please also read the part about the floor on page 3. Guarantee Heta wood stoves, subjected to a strict quality - Damage caused by improper use. control during production and before delivery to - Transportation costs for warranty repair.
Page 12
appendix a The Clean Air Act 1993 and Smoke Control that fuels burnt or obtained for use in smoke Areas Under the Clean Air Act local authorities control areas have been ”authorised” in Regu- may declare the whole or part of the district of lations and that appliances used to burn solid the authority to be a smoke control area.