Heta stove. Especially if you follow the following advice and instructions. The Vista and Vista S insert is approved according to EN 13229, NS 3058 and NS 3059. These approvals, means that the wood stove insert meets a variety of specifi- cations and requirements, ensuring it is made of quality materials, minimum environ- mental impact and that it has an optimum fuel economy.
Page 3
It is important that upon receipt check your Heta product completely and report any damage or defects to your dealer. The packaging must be disposed of as follows: Wood is untreated and able to burn in the stove.
With your new wood stove you should find the following: Operating / 1 Flue collar Betjenings- og 6000-022130 opstillingsvejledning Instruction manual vista og vista s pejseindsats 2 Chicane with flue collar 1013-018991 www.heta.dk dansk design . dansk kvalitet . dansk produktion Heta glove...
The combustion air is fully open, when the hand- front. Place pieces of wood equivalent to about le is pushed to the right. Closes gradually mo- 1,76 kg - Vista and 1,25 kg. - Vista S on top of ving the lever to the left. the embers.
Nominal heat out-put is 7 KW - Vista and 5 kW - Vista S, equivalent to the operating air at about Never use the stove if the 75% open, new wood can be added after ap- seals are loose. proimatley 50 minutes.
Good draft occurs when: 12 PA - Vista S. It is the draft that the stove has been tested and approved on. • The difference in temperature in the chimney The minimum draft is necessary to provide clean (warmer) and outside temperature (colder) burning, beautiful flame picture, as well as •...
Heta representative, who in turn will deposits may come to fall on the baffle plate, contact Heta to solve the claim. To file a claim remove and clean it. In cases where the wood please provide date of installation, picture of...
The nominal output is the output to which the stove has been tested. Testing is conducted with the combustion air open 75% and 4 peices of wood 15 cm long. Average temperature in the flue pipe connector: Vista - 319 and Vista S - 302...
1.17 Diagram for the maintenance Qualified Stove Owner Technicia Maintenance / Period Before 60-90 1st Year 2st Year Daily Autum days days days Cleaning the chimney (see. Chimney) Cleaning the chimney and stove Cleaning the stoves firebox Cleaning combustion air intake Checking / switch, gasket for door Checking / changing, gasket for glass Checking / changing gasket for flue pipe...
1.19 troubleshooting table - applies to all stove types Fault Cause Troubleshooting Solution Inadequate chimney draft. Lighting problems. When the You can test using a lighter whether Improve the chimney. The chimney only has stove is cold, smoke seeps flame is drawn into the combustion sufficient draft when it is hot.
1.20 Cleaning after sweeping or before replacing vermiculite stones Note: it may be necessary to clean/vaccum the holes and air ducts behind the rear stone Removal sequence of stones. Replace in reverse order. Starting with Fig. 6.
0023-018885 Rear stone, right - (Rib Landscape) 0023-018901 Bottom stone, left, vermiculit 0023-018902 Bottom stone, midten, vermiculite 0023-018903 Bottom stone, right, vermiculite 1.21 Parts stone - vista s Pos. No. Name Qty. 0023-020347 Rear stone, left - (Rib Landscape) 0023-020348...
Page 14
Parts Door vista and vista s Pos. No. Name Qty. 0008-0014 M6x6 0008-0035 M6x8 0008-1002 M6x6 0008-1009 M6x10 0008-1406 Nut M6 0008-3503 M6/12x1,6 0008-9082 M6x35 0016-0092 Stop for handle 0021-013611 Glass 10 0023-018940 Pakning ø12 x 1,85 m 11 0030-013025 Door...
Page 15
”unauthorised volved administrations. fuel” for use within a smoke control area unless The Vista and Vista S insert has been recommen- it is used in an ”exempt” appliance (”exempted” ded as suitable for use in smoke control areas from the controls which generally apply in the when burning dry wood logs.
1. Always ensure free access to any cleaning Distance from flammable floor: doors in a chimney. Vista 300 mm and Vista S 320 mm. 2. Always ensure ample fresh air to the room. 3. Exhaust/extraction fans in the house can re- Pay special attention to the distance from flam- duce or create negative draft in the chimney.
It is important that the chimney is fitted Vista has a nominal output of 7 kW Requires ad- with roof support so that the top panel of the ditional ventilation because it exceeds the 5 kW.
2.5 vista Clearances for installation en 13 229 The Building materials that are used in safety test and shown in illustrations on this page, has a thickness of 40 mm and a thermal conductivity of max. (=<0,066 W(m*K). Seen from the side...
Page 19
2.5 vista s Clearances for installation en 13 229 The Building materials that are used in safety test and shown in illustrations on this page, has a thickness of 40 mm and a thermal conductivity of max. (=<0,066 W(m*K). Seen from the side...
2.7 assembling the flue collar - 6000-022130 - 1913-018991 The flue collar (6000-022130) is mounted from inside the stove’s combustion chamber with 4 x M6x20 (0008-1114). 2.8 setting up the insert The entire convection box with the combustion Make sure the insert is level. chamber in must be adjusted in height using It must be ensured that the 4 gaskets lie just adjusting screws.
3. Connecting external air supply from below Fresh air connector ø100 mm - 6000- 023302 remove the bottom stones - see page 13. To ensure that the air damper is The air control installed correctly after mounting must be in the the external air supply, follow closed position! these instructions.
Page 24
Tighten the flex pipe around the ø100 mm pipe Replace the air control arm in the notch. on the fresh air connector. Lower it into place and fasten. Tighten screws, bushing and washers. Check that the air control moves freely. Check that all parts are seated correctly.
Page 25
3. vista s Connecting external air supply from below Fresh air connector ø100 mm - 6000-025950 remove the bottom stones - see page 12. The air control To ensure that the air damper is must be in the installed correctly after mounting...
Page 26
Replace the air control arm in the notch. Tighten the flex pipe around the ø100 mm pipe on the fresh air connector. Lower it into place and fasten. Tighten screws, bushing and washers. Check that all parts are seated correctly. Put the cover plate in place before placing the bottom stones again.
Adress Jupitervej 22, DK 7620 Lemvig EU Declaration of Conformity E-mail heta@heta.dk Website www.heta.dk DoC Vista 2527-2020 Telephone +45 9663 0600 Product fiche Model identifier Vista The identified product described above is in Notified body relevant to the assessment and verification of...