Ignition 2bright Pint TW200 IP User Manual page 43

Led par
Table of Contents

Advertisement

Calibrating colour temperature
1.
Press [MENU] and then [UP] or [DOWN] repeatedly until the display shows 'Settings' .
Confirm with [ENTER].
2.
Press [UP] or [DOWN] repeatedly until the display shows 'Service' . Confirm with [ENTER].
3.
Press [UP] or [DOWN] repeatedly until the display shows 'Calibration' . Confirm with
[ENTER].
ð You are prompted to enter a password.
4.
Enter the password 50. Confirm with [ENTER].
5.
Use [UP] or [DOWN] to select the value for the colour temperature calibration. The fol‐
lowing table shows the available options.
Menu level 4
'Warm'
'Cold'
'Amber'
6.
Press [ENTER] to accept the selection.
Menu level 5
Function
'000...255'
Calibrating warm white
'000...255'
Calibrating cold white
'000...255'
Calibrating amber
Operating
2bright Pint TW200 IP
43
LED PAR