Adaptec DuraStor 6200SR User Manual page 59

Operator control panel
Hide thumbs Also See for DuraStor 6200SR:
Table of Contents

Advertisement

Table 5-2. Alarm Thresholds
Alarm Threshold
CPU temperature
Warning—0°C–5°C and
65°C–70°C
Shutdown—0°C, 70°C,
<0°C, and >70°C
Onboard temperature
Warning—0°C–5°C and
45°C–50°C
Shutdown—0°C, 50°C,
<0°C, and >50°C
VCC voltage
Warning—5V -3.5% and
+6.5%
Shutdown—5V -6.5% and
+10%
12V voltage
Warning—12V -8% and
+8%
Shutdown—12V -10% and
+10%
Configuring the RAID Controller
What To Do When the Alarm Sounds
Check Adaptec Disk Array
I
Administrator to confirm what the
alarm means. See
Monitoring System
Check the ambient temperature and
I
lower it, if needed. Ambient
temperature should be less than
45°C.
Same as above for the CPU
I
temperature.
Check Adaptec Disk Array
I
Administrator to confirm what the
alarm means. See
Monitoring System
If it is a warning alarm, let the
I
controller continue to operate.
If it is a shutdown alarm, turn off
I
the power to the controller and send
it for service.
Same as above for the VCC voltage.
I
Chapter 3,
Status.
Chapter 3,
Status.
5-12