GALLERY Classic Eco Installation Instructions Manual page 8

Table of Contents

Advertisement

FITTING THE THERMAL SWITCH GUARD
Using the two screws already fitted to the rear of the stove, secure the thermal switch guard
to the rear of the appliance. See Fig. 4
Fig.4 Fitting the thermal switch guard
POSITIONING THE STOVE
Clearances from non-combustible material in the fireplace opening must be at least 160mm on the
left side, 160mm on the right hand side and 105mm at the back. See Fig. 5. These distances must be
extended to a minimum clearance of 400mm from any combustible material.
Fig.5 Clearances
8