GALLERY Classic Eco Installation Instructions Manual page 21

Table of Contents

Advertisement

Hearth Requirements
Is the hearth constructed from non-combustible material and protection sufficiant?
Is the hearth a minimum of 12mm thick with a minimum floor to top surface of 50mm
(BS5871) or as per manufacturer's instructions?
Firebox and Fuel bed
Has the fuel bed (logs, vermiculite) been fitted to the manufacturer's instructions?
Gas Supply
Has an isolation tap/restrictor inlet elbow been fitted for servicing?
Has the gas supply been thoroughly purged prior to connection to remove any debris?
Has a gas tightness test been completed prior to breaking into the gas supply and following
completion of the installation? (IGEM/UP/1B)
Record burner gas pressure reading? If only the supply pressure is available a gas rate must
be undertaken. (GSIUR REG 26/9C)
Record inlet gas pressure (working pressure) reading (all gas appliances running).
Spillage Test
Installation passes smoke match test with any extractor fans turned on?
Installation
Has the appliance been installed and commissioned in accordance with the manufacturer's
instructions?
Has the appliance been installed with the correct clearance to combustible materials as per
the manufacturer's instructions?
The operation of the appliance and controls have been demonstrated to the customer
including battery replacement where applicable?
Has the appliance been registered with the Local Authority as detailed on the Gas Safe
website which forms part of the warranty?
Customer's signature:
(To confirm satisfactory demonstration and receipt of manufacturer's literature)
Commissioning Engineer's signature:
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No