GALLERY Classic Eco Installation Instructions Manual page 17

Table of Contents

Advertisement

• Close the stove door, replace the screw securing the door
• Check the supply pressure as described in the TECHNICAL INFORMATION section (P.5)
• Complete a gas tightness test
• Check all controls, safety devices including the flame picture and that the fire is working safely
accordance with the manufacturer's instructions
• Check the flue in accordance with regulation 26(9) Ensure there are no signs of metal fatigue,
distortion, discolouration, sooting and distress
• Ensure correct operation of the flue and perform a spillage test as described in CHECK FOR
SPILLAGE section (see page 14) and flue how test.
• Complete service and maintenance log on page 18
• The thermal switch rating is 120ºC. Quote this rating if ordering a new switch.
DOOR SEAL
If required the door seal can be adjusted/tightened as follows:
1. Slacken door locking screw and open the stove door.
2. Slacken handle locking screw and remove handle.
3. Remove 1 spacer washer and move to the other side of the door.
4. Reassemble in reverse order.
Handle locking screw
Move spacer
washer to here
Spacer washers
Door locking screw
17