Commissioning The Stove - GALLERY Classic Eco Installation Instructions Manual

Table of Contents

Advertisement

Commissioning the stove

MANUALLY OPERATED STOVES
Once the fire is in place, connected, flued correctly, and the logs are in place, you can proceed with
lighting the stove and ensuring all the features are working correctly.
The control knob is located behind the right-hand foot of the stove.
The pilot light is centrally located.
Should the stove be extinguished for any reason wait 3 minutes before attempting re-ignition.
Connect a suitable pressure gauge to the inlet pressure test point to check the correct inlet pressure.
Fig.10 Orientation off appliance
Fig.11 Orientation on appliance
LIGHTING THE PILOT
Depress control knob fully. Whilst depressed turn knob slowly through 80° anti-clockwise to PILOT
setting. Continue to depress the control knob, a click should be heard and the pilot should light. Repeat
until pilot is visibly lit. If necessary, the operation of the spark can be viewed by temporarily opening
the front door.
Keep knob depressed at this point for 10-15 seconds and release the knob. The pilot light will remain lit.
HIGH SETTING
If the pilot is not already lit, light the pilot as described above. With control knob at PILOT setting,
depress and turn anti-clockwise to HIGH setting and release the knob.
LOW SETTING
If the stove is not already lit on HIGH setting, ignite stove to HIGH setting as described above. Turn the
control knob progressively in an anti-clockwise direction until the desired level is achieved, up to the
LOW setting. Check that the supply pressure is 20 mbar ± 1 mbar.
12