Removing A Hard Disk Drive - IBM 7985 Problem Determination And Service Manual

Table of Contents

Advertisement

10. Slide the server into the rack.
11. Connect the cables and power cords.
12. Turn on all attached devices and the server.
13. When you restart the server, you will be given the opportunity to import the

Removing a hard disk drive

To remove a hard disk drive from a hot-swap bay, complete the following steps.
3.5-inch drives
Tray handle
122
IBM System x3655 Type 7985 and 7943: Problem Determination and Service Guide
2. Turn the new ServeRAID SAS controller so that the keys on the bottom edge
align correctly with the connector.
3. Firmly press the ServeRAID SAS controller straight down into the connector by
applying pressure on both ends of the controller simultaneously. The retaining
clips snap into the locked position when the controller is firmly seated in the
connector.
Note: If there is a gap between the controller and the retaining clips, the
controller has not been correctly installed. In this case, open the retaining clips
and remove the controller; then, reinsert the controller.
4. If you are installing a ServeRAID-8k SAS controller, complete the following
steps.
a. Remove the battery from the ServeRAID-8k SAS controller package.
b. Slide the battery mounting tabs into the battery mounting clips on the wall
of the power supply bay next to the connector.
c. Connect the ServeRAID-8k SAS controller battery cable to the ServeRAID
SAS controller.
5. Reposition the SAS cable.
6. Install the fan-bracket assembly (see "Installing the fan-bracket assembly" on
page 137).
7. Install the air baffle ("Installing the air baffle" on page 112).
8. Install the riser-card assembly (see "Installing the riser-card assembly" on page
155).
9. Install the cover.
existing RAID configuration to the new RAID controller.
Hard disk drive

Advertisement

Table of Contents
loading

This manual is also suitable for:

7943

Table of Contents