IBM 7985 Problem Determination And Service Manual page 188

Table of Contents

Advertisement

v Erase all data from a hard disk drive and return the disk drive to the
v View the RAID configuration and associated devices
v Monitor the operation of the RAID controllers
To perform some tasks, you can run ServeRAID Manager as an installed program.
However, to configure the RAID controller and perform an initial RAID configuration
on the server, you must run ServeRAID Manager in Startable CD mode, as
described in the instructions in this section.
See the ServeRAID documentation on the IBM ServeRAID Support CD for
additional information about RAID technology and instructions for using ServeRAID
Manager to configure the RAID controller. Additional information about ServeRAID
Manager is also available from the Help menu. For information about a specific
object in the ServeRAID Manager tree, select the object and click Actions →Hints
and tips.
Configuring the RAID controller: By running ServeRAID Manager in Startable
CD mode, you can configure the RAid controller before you install the operating
system. The information in this section assumes that you are running ServeRAID
Manager in Startable CD mode.
To run ServeRAID Manager in Startable CD mode, turn on the server; then, insert
the CD into the CD-RW/DVD drive. If ServeRAID Manager detects an unconfigured
controller and ready drives, the Configuration wizard starts.
In the Configuration wizard, you can select express configuration or custom
configuration. Express configuration automatically configures the controller by
grouping the first two physical drives in the ServeRAID Manager tree into an array
and creating a RAID level-1 logical drive. If you select custom configuration, you
can select the two physical drives that you want to group into an array and create a
hot-spare drive.
Using express configuration: To use express configuration, complete the following
steps:
1. In the ServeRAID Manager tree, click the controller.
2. Click Express configuration.
3. Click Next.
4. In the"Configuration summary" window, review the information. To change the
5. Click Apply; when you are asked if you want to apply the new configuration,
6. Exit from ServeRAID Manager and remove the CD from the CD-RW/DVD drive.
7. Restart the server.
Using custom configuration: To use custom configuration, complete the following
steps:
170
IBM System x3655 Type 7985 and 7943: Problem Determination and Service Guide
factory-default settings
configuration, click Modify arrays.
click Yes. The configuration is saved in the controller and in the physical drives.
1. In the ServeRAID Manager tree, click the controller.
2. Click Custom configuration.
3. Click Next.
4. In the "Create arrays" window, from the list of ready drives, select the drives
that you want to group into the array.
5. Click the (Add selected drives) icon to add the drives to the array.

Advertisement

Table of Contents
loading

This manual is also suitable for:

7943

Table of Contents