2.5-inch drives
Important: Install only SAS 2.5-inch hard disk drives in this server.
Attention:
than 10 minutes without either a drive or a filler panel installed in each bay.
1. Install the hard disk drive in the hot-swap bay:
2. Check the hard disk drive status LED to verify that the hard disk drive is
124
IBM System x3655 Type 7985 and 7943: Problem Determination and Service Guide
To maintain proper system cooling, do not operate the server for more
a. Make sure that the tray handle is open (that is, perpendicular to the drive).
b. Align the drive assembly with the guide rails in the bay.
c. Gently push the drive assembly into the bay until the drive stops.
d. Push the tray handle to the closed (locked) position.
operating correctly.
If the amber hard disk drive status LED for a drive is lit continuously, that drive
is faulty and must be replaced. If the green hard disk drive activity LED is
flashing, the drive is being accessed.