11. MAX GAIN Adjustment
Setting the minimum illumination.
If it is not consistent, the image level required for taking
subjects in low illuminance will not be produced (dark).
Subject
Clear chart
(Color bar standard picture frame)
Measurement Point
DDS display of TV monitor (*)
Measuring Instrument
Adjustment Page
F
Adjustment Address
31
Specified Value
C0 to FF
n
* : The right two digits of the display data at the right
bottom side of TV monitor is the object data.
00 XX XX
Adjusting method
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 11, and set data: 02, and press
the PAUSE button of the adjusting remote commander.
3) Select of page: 0, address: 03, and set data: 01.
4) Select page: 2, address: 40, and set data: 02.
5) Select page: 2, address: 56, and set data: 40.
6) Select page: 2, address: 01, set data: 19, and press the
PAUSE button of the adjusting remote commander.
7) Select page: F, address: 31, set data: 30, and press the
PAUSE button of the adjusting remote commander.
8) Check that the DDS display data (*) lies within the
specified value.
Processing after Completing Adjustments
1) Select page: D, address: 11, and set data: 00, and press
the PAUSE button of the adjusting remote commander.
2) Select page: 2, address: 01, and set data: 00, and press
the PAUSE button of the adjusting remote commander.
3) Select page: 2, address: 40, and set data: 00.
4) Select page: 2, address: 56, and set data: 00.
5) Select page: 0, address: 03, and set data: 00.
6) Select page: 0, address: 01, and set data: 00.
2-24
Object data
12. Auto White Balance Standard Data Input
Subject
Clear chart
(Color bar standard picture frame)
Adjustment Page
F
Adjustment Address
70 to 73
m
. Perform "Color Reproduction Adjustment" before this
adjustment.
. Check that the data of page: 2, address: 02 is 00. If not,
turn the power of the unit OFF/ON.
Adjusting method
1) Select page: 0, address: 01, and set data: 01.
2) Wait for 2 seconds.
3) Select page: 2, address: 01, and set data: 11, and press
the PAUSE button of the adjusting remote commander.
4) Select page: 2, address: 01, and set data: 0D, and press
the PAUSE button of the adjusting remote commander.
(When the standard data is take in, the data will be
automatically input to page: F, address: 70 to 73.)
5) Select page: 2, address: 02, and check that the data is
"01".
6) Perform "Auto White Balance Adjustment".
Processing after Completing Adjustments
1) Select page: 2, address: 01, and set data: 00, and press
the PAUSE button of the adjusting remote commander.
2) Select page: 0, address: 01, and set data: 00.
EVI-D100/EVI-D100P