Camera Adjustments - Sony EVI-D100 Service Manual

Color video camera
Hide thumbs Also See for EVI-D100:
Table of Contents

Advertisement

Address
Initial Value
NTSC PAL
EF
F0
F1
F2
F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
2-16
Remark
Fixed data-1
Fixed data-2
Fixed data-1

2-3. Camera Adjustments

1. 28 MHz Origin Oscillation Adjustment (VC-266
board (NTSC), VC-266P board (PAL))
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the
color will become inconsistent.
Subject
Not required
Pin != of IC105
Measurement Point
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
2C
Pin != of IC105 :
Specified Value
f = 14.318181 MHz ± 68 Hz (NTSC)
f = 14.187500 MHz ± 68 Hz (PAL)
NTSC Model:
EVI-D100/D100C
PAL Model:
EVI-D100P/D100CP
Adjusting method
1) Select page: 0, address: 01, and set data: 01.
2) Select page: F, address: 2C, change the data and set the
clock frequency (f) to the specified value.
3) Press the PAUSE button of the adjusting remote
commander.
4) Select page: 0, address: 01, and set data: 00.
EVI-D100/EVI-D100P