2-2. Initialization of D, E, F, Page Data
1. Initializing the D,E,F Page Data
m
. If "Initializing the D, E, F Page Data" is performed, all
data of the D page, E page and F page will be initialized.
(It is impossible to initialize a single page.)
. If the D,E,F page data has been initialized, "Modifica-
tion of D, E, F Page Data" and all adjustments need to be
performed again.
. < > : NTSC model (EVI-D100/D1000)
[ ] : PAL model (EVI-D100P/D100CP)
Adjusting page
Adjusting Address
Adjusting page
Adjusting Address
Adjusting page
Adjusting Address
Initializing Method
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 2, address: 00, and set data: 55 <NTSC>
or data : 51 [PAL].
3) Select page: 2, address: 01, set data: 55 <NTSC> or
data : 51 [PAL], and press the PAUSE button of the
adjusting remote commander.
4) Select page: 2, address: 02, and check that the data is
01.
5) Select page: 3, address: 00, and set data: 29.
6) Select page: 3, address: 01, set data: 29, and press the
PAUSE button of the adjusting remote commander.
7) Select page: 0, address: 01, and set data: 00.
8) Perform "Modification of D, E, F Page Data".
2-8
D
00 to 6F
F
00 to FF
E
00 to FF
2. Modification of D, E, F Page Data
If the D, E, F page data has been initialized, change the
data of the "Fixed data-2" address shown in the following
tables by manual input.
Modifying Method
1) Before changing the data, select page: 0, address: 01,
and set data: 01.
2) New data for changing are not shown in the tables
because they are different in destination.
When changing the data, copy the data built in the
same model.
n
If copy the data built in the different model, the
camcorder may not operate.
3) When changing the data, press the PAUSE button of
the adjusting remote commander each time when
setting new data to write the data in the non-volatile
memory.
4) Check that the data of adjustment addresses is the
initial value. If not, change the data to the initial value.
5) After completing "Modification of D, E, F Paga Data"
select page: 0, address: 01, and set data: 00. Also
perform all adjustments.
EVI-D100/EVI-D100P