Selecting The Mode Of Operation - Racal Instruments 1256 Manual

Switching system
Table of Contents

Advertisement

1256 User Manual
Selecting the Mode
of Operation
Digital Module Operation 7-4
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
(@7(0))
Ports 0 and 11 on module 7:
(@7(0,11))
Ports 0 through 11 on module 7:
(@7(0:11))
Port 0 on module 7; port 4 on module 8:
(@7(0),8(4))
Ports 0, 2 and 3 on module 7; ports 7 through 11 on module 8:
(@7(0,2,3),8(7:11))
The
mode
of
operation
DIGITAL:CONFIGURE command. This command has the following
syntax:
:DIGital
:CONFigure <port>
Examples of this command are shown below:
To set all ports of the 1260-114 module with address 7 to the
asynchronous mode of operation:
DIG:CONF (@7(0))
To set ports 0 through 3 to the synchronous mode, and ports 4
through 11 to the asynchronous mode:
DIG:CONF (@7(12)): DIG:CONF (@7(4))
To read the presently selected mode of operation for port 10 on
module 7, issue the following command. The reply returns "SYNC"
if it is synchronous, or "ASYN" if it is asynchronous:
DIG:CONF? (@7(10))
Publication No. 980855 Rev. A
may
be
selected
EADS North America Test and Services
using
the

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

407734

Table of Contents