PSETUP

Operation 3-10
PSETUP <module address>[;<module address>]....
This command causes the Option 01 to output a character string
describing the setup of the switching system Option 01 and
switching modules. An example of a character string obtained in
response to a "PSETUP 0-12" command is given below.
000. Model 1260 Universal Switch Controller
000. OS Rev 1.2 1260
000. CNF OFF
000. DLY 0
000. EOI 0
000. EQU
000. EXCL
000. SCAN ON
000. SLIST 0
000. SRQMASK 40
000. SYNC 8
000. TTLTRG 0
000. PUPRCL OFF
012. 1260-40A 4 x 24 Signal Matrix
012. BBM
012.END
The character string output by the 1260 Option 01 is
made up of multiple lines and contains carriage-
return, line-feed pairs. These will terminate the output
string. The PSETUP output string must be read
repeatedly until all lines of the output have been read
for all modules specified. The final line output by the
Option 01 is <module address>.END where <module
address> is the VXI chassis slot that the highest
module address present in the VXI chassis.
The module address for PDATAOUT and PSETUP
commands may specify a range of module addresses
by using the syntax <start module address>-<end
module address>. The Option 01 will output data for
all modules between the starting and ending module
addresses that are installed in the 1260.