1260 Series User Manual

PUPRCL

READ

RECALL

RESET

PUPRCL <ON|OFF>
This command enables and disables the automatic recall of non-
volatile memory location 1 at power up. The configuration in non-
vol location 1 is stored by the use of the STORE command. Refer
to the appropriate paragraph for details of the STORE command.
If non-volatile location 1 is cleared and PUPRCL is
ON, no recall will take place at power up.
READ <module address>.<module specific syntax>
This command is supported by digital cards only. Refer to the
individual module sections for a description of the syntax and
functions performed.
RECALL <non-vol location>
where <non-vol location> = 1|2|.......|50
This command will set all switching modules in the VXI chassis to
the configuration stored in the non-volatile location specified. The
physical location of the modules in the chassis slots is unimportant
as long as the same type modules are at the same module
addresses as when the switching system configuration was stored,
and the rules governing module locations are observed. Note that
an error will be generated if an attempt is made to RECALL a
memory setting into a switching system configuration that differs
from the configuration present when the memory setting was
stored. An error will also be generated if an attempt is made to
RECALL a memory setting from an empty location.
RESET
A delay of at least 100 msec may be required after a
RESET command before issuing the next command.
This command causes all switching modules to be set to their de-
energized states.