PDATAOUT and
PSETUP Module
Identification
Module Specific Syntax 3-8
they have to be the same type of module.
Example:
Assume the 1260 Option 01 controls a 1260-40A card with module
address 2, and a 1260-18 card with module address 7.
EXCL 2.0000-0123E;7.000-110E;2.0200-0323;7.111-151
This example defines three exclude groups. The first consists
solely of 1260-40A relays, channels 0000 through 0123. The
second consists solely of 1260-18 relays, channels 000 through
110. The third consists of a mix of 1260-40A relays and 1260-18
relays.
After an EXCL command is executed, the 1260 Option 01 will
ensure that at most one relay in any exclude group is closed at
one time. For example, suppose relay 7.103 is presently closed.
Closing relay 7.000 will cause the 1260 Option 01 to first open
relay 7.103 before closing relay 7.000. Similarly, if relay 7.111 is
presently closed, then closing relay 2.0319 will cause the 1260
Option 01 to first open relay 7.111 before closing relay 2.0319.
The first line of the reply to the PDATAOUT and PSETUP
commands for the 1260-18 shall be:
XXX. 1260-18 HIGH DENSITY BASIC SWITCH MODULE
where:
XXX is the module address of the 1260-18 ("001" to "012"). All
other reply lines for these commands shall follow the syntax used
for all of the other 1260 series relay cards. Note that the lines of
the reply for the PDATAOUT command will contain relay
descriptors which follow the syntax described in this chapter.
User Manual 1260-18