ADF Web PROFINET/SNMP Agent User Manual

Profinet / snmp agent - converter

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.100
English
PROFINET / SNMP Agent - Converter
(Order Code: HD67613-A1)
For Website information:
www.adfweb.com?Product=HD67613
For Price information:
www.adfweb.com?Price=HD67613-A1
Benefits and Main Features:
Very easy to configure
Triple Electrical isolation
Temperature range: -40°C/+85°C (-40°F/+185°F)
User Manual
ADFweb.com S.r.l.
User Manual PROFINET / SNMP Agent
Document code: MN67613_ENG
For other PROFINET products see also the following link:
Converter PROFINET to
www.adfweb.com?Product=HD67078
www.adfweb.com?Product=HD67090
www.adfweb.com?Product=HD67178
www.adfweb.com?Product=HD67600
www.adfweb.com?Product=HD67601
www.adfweb.com?Product=HD67602
www.adfweb.com?Product=HD67603
www.adfweb.com?Product=HD67604
www.adfweb.com?Product=HD67605
www.adfweb.com?Product=HD67606
www.adfweb.com?Product=HD67607
www.adfweb.com?Product=HD67608
www.adfweb.com?Product=HD67609
www.adfweb.com?Product=HD67610
www.adfweb.com?Product=HD67611
www.adfweb.com?Product=HD67612
www.adfweb.com?Product=HD67614
www.adfweb.com?Product=HD67660
www.adfweb.com?Product=HD67679
www.adfweb.com?Product=HD67719
www.adfweb.com?Product=HD67818
www.adfweb.com?Product=HD67848
Do you have your customer protocol? Then go to:
www.adfweb.com?Product=HD67003
Do you need to choose a device? Do you want help?
www.adfweb.com?Cmd=helpme
Revision 1.100
Page 1 of 28
(M-Bus)
(M-Bus Wireless)
(SNMP Manager)
(NMEA 2000)
(Serial)
(Modbus Master)
(Modbus Slave)
(PROFIBUS Master)
(PROFIBUS Slave)
(CAN)
(CANopen)
(DeviceNet Master)
(DeviceNet Slave)
(J1939)
(Modbus TCP Master)
(Modbus TCP Slave)
(DMX)
(EtherNet/IP)
(BACnet Slave)
(BACnet Master)
(KNX)
(DALI)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PROFINET/SNMP Agent and is the answer not in the manual?

Questions and answers

Summary of Contents for ADF Web PROFINET/SNMP Agent

  • Page 1 User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 1 of 28 Industrial Electronic Devices User Manual Revision 1.100 English PROFINET / SNMP Agent - Converter (Order Code: HD67613-A1) For Website information: www.adfweb.com?Product=HD67613 For other PROFINET products see also the following link: For Price information: Converter PROFINET to www.adfweb.com?Product=HD67078...
  • Page 2: Updated Documentation

    User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 2 of 28 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Page Dear customer, we thank you for your attention and we remind you that INDEX you need to check that the following document is: UPDATED DOCUMENTATION Updated REVISION LIST...
  • Page 3: Security Alert

    User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 3 of 28 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4: Examples Of Connection

    User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 4 of 28 Industrial Electronic Devices EXAMPLES OF CONNECTION: ADFweb.com S.r.l.
  • Page 5: Connection Scheme

    User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 5 of 28 Industrial Electronic Devices CONNECTION SCHEME: Figure 1: Connection scheme for HD67613-A1 ADFweb.com S.r.l.
  • Page 6 User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 6 of 28 Industrial Electronic Devices CHARACTERISTICS: The HD67613-A1 is a PROFINET / SNMP Converter. It allows for the following characteristics: Up to 1024 bytes in reading and 1024 bytes in writing; Isolation between Ethernet - Power Supply;...
  • Page 7: Power Supply

    User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 7 of 28 Industrial Electronic Devices POWER SUPPLY: The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below. Vmin Vmax Vmin Vmax...
  • Page 8: Function Modes

    User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 8 of 28 Industrial Electronic Devices FUNCTION MODES: The device has got two function modes depending on the position of the ‘Dip2 of Dip-Switch A’: The first, with ‘Dip2 of Dip-Switch A’ at “OFF” position, is used for the normal working of the device. The second, with ‘Dip2 of Dip-Switch A’...
  • Page 9 User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 9 of 28 Industrial Electronic Devices LEDS The device has got six LEDs that are used to give information about the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode ON: Device powered...
  • Page 10 User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 10 of 28 Industrial Electronic Devices ETHERNET: The PROFINET and SNMP connection and the updating of the converters must be made using Connector3 and/or Connector4 of HD67613-A1 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m. The cable has to conform to the T568 norms relative to connections in cat.5 up to 100 Mbps.
  • Page 11 User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 11 of 28 Industrial Electronic Devices USE OF COMPOSITOR SW67613: To configure the Converter, use the available software that runs with Windows called SW67613. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 12: New Configuration / Open Configuration

    User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 12 of 28 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a programmable “PROFINET / SNMP Agent - Converter”...
  • Page 13: Software Options

    User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 13 of 28 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 14: Set Communication

    User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 14 of 28 Industrial Electronic Devices SET COMMUNICATION: This section define the fundamental communication parameters of two buses, PROFINET and SNMP. By Pressing the “Set Communication” button from the main window for SW67613 (Fig. 2) the window “Set Communication”...
  • Page 15: Set Snmp Access

    User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 15 of 28 Industrial Electronic Devices SET SNMP ACCESS: By pressing the “Set SNMP Access” button from the main window for SW67613 (Fig. 2) the “Set SNMP Access” window appears (Fig. 4). In this section, it is possible to create the OIDs for SNMP side to read or write using GET and SET commands or to be sent as TRAP messages.
  • Page 16 User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 16 of 28 Industrial Electronic Devices The data of the columns in the “SNMP Write” have the following meanings: field “Enable” checked, the SNMP OID is enabled; field “Community Name”...
  • Page 17 User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 17 of 28 Industrial Electronic Devices PROFINET XML: By pressing the “PROFINET XML” button it is possible to save the xml file for the PROFINET side. With this feature you can save the configuration of the converter of the PROFINET side. SNMP MIB: By pressing the “SNMP...
  • Page 18: Update Device

    User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 18 of 28 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary. If you don’t know the actual IP address of the device you have to use this procedure: Turn OFF the Device;...
  • Page 19 User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 19 of 28 Industrial Electronic Devices Note: When you install a new version of the software, if it is the first time it is better you do the update of the Firmware in the HD67613 device.
  • Page 20: Snmp Communication

    User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 20 of 28 Industrial Electronic Devices SNMP COMMUNICATION In order to read/write the data from/to PROFINET side, it is necessary to use specific SNMP commands in order to see the SNMP Input and write the SNMP Output.
  • Page 21 User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 21 of 28 Industrial Electronic Devices Each SNMP variable created will have its own OID and it will be created following this rule: OID 1 (first row of “Set SNMP Access -> SNMP Read” table): .1.3.6.1.4.1.49314.1.1.1.4.9.1 OID 2 (second row of “Set SNMP Access ->...
  • Page 22 User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 22 of 28 Industrial Electronic Devices Writing PROFINET data from SNMP: In order to write the data from the HD67613, it is necessary to use the SET command. Each OID defined in the section “Set SNMP Access ->...
  • Page 23 User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 23 of 28 Industrial Electronic Devices Each SNMP variable created will have its own OID and it will be created following this rule: OID 1 (first row of “Set SNMP Access -> SNMP Write” table): .1.3.6.1.4.1.49314.1.1.1.5.9.1 OID 2 (second row of “Set SNMP Access ->...
  • Page 24 User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 24 of 28 Industrial Electronic Devices TRAP messages from SNMP: All the OIDs defined in the “Set SNMP Access -> SNMP Read” table can be sent as TRAP messages too. The TRAP messages are contained in the MIB tree and they have these OIDs: TRAP 1 (first row of “Set SNMP Access ->...
  • Page 25: Mechanical Dimensions

    User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 25 of 28 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 8: Mechanical dimensions scheme for HD67613-A1 ADFweb.com S.r.l.
  • Page 26: Ordering Informations

    User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 26 of 28 Industrial Electronic Devices ORDERING INFORMATIONS: The ordering part number is formed by a valid combination of the following: HD67613 – xx Connectors Type 1: Removable 5mm Screw Terminal Enclosure Type A: 1M, 35mm DIN Rail mounting Device Family...
  • Page 27: Other Regulations And Standards

    User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 27 of 28 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 28: Warranties And Technical Support

    User Manual PROFINET / SNMP Agent Document code: MN67613_ENG Revision 1.100 Page 28 of 28 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following: Obtain a Product Return Number (PRN) from our internet support at www.adfweb.com.

This manual is also suitable for:

Hd67613-a1

Table of Contents