Paging Through The Protocol - ProMinent ProMaqua Bello Zon CDLb Series Operating Instructions Manual

Chlorine dioxide systems with external pre-storage vessel
Table of Contents

Advertisement

12.3

Paging through the protocol

Page through
protocol?
16.
Only CDLb 120: Route the tube back into the external pre-storage
module.
17.
Only CDLb 6 ... 55: Remove the PVC tube from the 3-way valve and
fit the plug.
18.
Carefully insert the acid suction lance in the red "acid" vessel and
secure.
19.
Carefully insert the chlorite suction lance in the blue "chlorite" vessel
and secure.
20.
Empty the collecting vessel holding the rinsing water into a drain.
21.
Empty the water buckets one after the other into a drain and flush
with plenty of water between buckets.
22.
Press the
using the
Event:
31
t 29:07:44
Metering mon-
itoring NaClO2
Event:
30
t 23:13:02
System off
Event:
1
t 00:00:02
Runtime and
ClO2 reset
The protocol function records all important events in the control of the
Bello Zon
®
CDLb system, in a power-failure secure manner, see Tab.
Ä on page 47 . It numbers the events sequentially and specifies the time
of the event. If there is a power failure, the internal clock continues to run.
The protocol function starts with the first commissioning in the factory.
The control counts the time points "t" of the new events starting from the
last resetting of the operating time (in hours : minutes : seconds). In gen‐
eral this is the date of the last maintenance.
The control stores old events when resetting the operating time. However,
they keep their old time points "t".
Paging through the protocol is undertaken using the
CAUTION!
Only CDLb 6 ... 55: Always refit the plug in the flushing
connector of the 3-way valve!
[ENTER] to exit the setting menu 'Rinse system?' and
[CHANGE] key, change to the 'OFF' display.
Operation
B0484
[Arrow keys] .
47