Emerson ATCA-F120 Installation And Use Manual page 99

Table of Contents

Advertisement

Table 4-7 IPMI Sensors Overview (continued)
Sensor Name
F120 CPLD Code
F120 CPLD Vers.
F120 FPGA Vers.
F120 HotSwap
F120 IPMB0 State
F120 IPMC
F120 Watchdog
FIX1 Temp
FIX2 Temp
HotSwap AMC B1
HotSwap AMC B4
HotSwap F120 RTM
OS Boot
Payload Power
SYS FW PROGRESS
Top Edge Temp
4.10.2 Available IPMI Drivers
An IPMI driver is included in the Linux distribution available for the blade.
4.10.3 Watchdog
The IPMC contains two watchdogs.
One watchdog is implemented in the IPMC hardware and supervises the operation of the IPMC
itself. This watchdog is not configurable and is permanently enabled.
ATCA-F120 Installation and Use (6806800D06F)
Sensor Type
Emerson-specific Discrete
Digital
Emerson Firmware Revision
Emerson Firmware Revision
PICMG 3.0: FRU HotSwap
PICMG 3.0: IPMB Physical
Link
Emerson IPMC Status
Watchdog 2
Temperature
Temperature
PICMG 3.0: FRU HotSwap
PICMG 3.0: FRU HotSwap
PICMG 3.0: FRU HotSwap
OS Boot
Current
System Firmware Progress
Temperature
Functional Description
Availability
Always
While payload powered
Always
Always
Always
Always
Always
Always
Always
Always
Always
Always
While payload powered
Always
While payload powered
Always
99

Advertisement

Table of Contents
loading

Table of Contents