Installation Procedure
The following describes how to install an AMC module into AMC bay B1 and B4. The installation
procedure assumes that the AMC module is being hot-inserted, that means the ATCA-F120 is
powered. The procedure for the cold insertion, that means the ATCA-F120 is not powered, is
the same, except that you need not wait for the blue LED indications to proceed.
1. Make sure you are in an ESD-safe environment.
2. Identify the AMC bay to be used for the installation.
Refer to
3. If the required AMC bay is occupied by an AMC filler panel, you will need to remove
the filler panel before proceeding with the installation procedure. The removal
procedure for the filler panel is the same as described in the Removal procedure
which follows immediately after this procedure. Ignore steps that mention the blue
LED.
4. Ensure that the AMC module handle is in the extracted position: pulled outward,
away from the face plate.
5. Using your thumb, apply equal and steady pressure on the face plate as necessary
to carefully slide the AMC module into the guides rails.
6. Continue to gently push the module along the guide rails till the module is fully
engaged with the connector.
Avoid using excessive force during this operation.
7. Wait for the blue LED to glow.
The blue LED glows when the AMC module is completely engaged with the
connector.
8. Press module handle inwards towards the face plate to lock the AMC module on
AMC bay.
9. Wait for the blue LED to perform a series of long blinks.
ATCA-F120 Installation and Use (6806800D06F)
Supported AMC Modules on page 52
Hardware Preparation and Installation
for more details.