Emerson ATCA-F120 Installation And Use Manual page 45

Table of Contents

Advertisement

Table 2-4 Switch Settings (continued)
Switch
SW2-4
SW3-1
SW3-2
SW3-3
SW3-4
SW4-1
SW4-2
SW4-3
SW4-4
2.6
Blade Installation and Removal
The blade is fully compatible to the AdvancedTCA standard and is designed to be used in
AdvancedTCA shelves.
ATCA-F120 Installation and Use (6806800D06F)
Hardware Preparation and Installation
Description
User flash #2 write-protection. See
Map on page 109
for further details.
OFF: User flash #2 write-enabled (default)
ON: User flash #2 write-protected
Boot flash selection. See
Boot Flashes on page 83
page 109
for further details.
OFF: IPMI selects boot flash (default)
ON: Switch SW3-2 determines boot flash
Determines boot flash (only if switch SW3-1 is set to ON). See
Flashes on page 83
for further details.
OFF: Blade boots from boot flash #1 (default)
ON: Blade boots from boot flash #2
Watchdog timer enabling. This switch allows to enable/disable the
watchdog inside the FPGA. See
details.
OFF: Watchdog enabled (default)
ON: Watchdog disabled
Reserved (default: OFF)
Reserved (default: OFF)
Reserved (default: OFF)
Reserved (default: OFF)
Reserved (default: OFF)
User Flashes on page 83
and
Memory Map on
Glue Logic FPGA on page 81
and
Memory
Boot
for further
45