Specifications; Introduction; General - Tait T880 II Series Adjustment Manual

Base station equipment
Table of Contents

Advertisement

C1.4
T881 General Information
1.2

Specifications

1.2.1

Introduction

The performance figures given are minimum figures, unless otherwise indicated, for
equipment tuned with the maximum switching range and operating at standard room
temperature (+22°C to +28°C) and standard test voltage (13.8V DC).
Where applicable, the test methods used to obtain the following performance figures are
those described in the EIA specification. However, there are several parameters for
which performance according to the CEPT specification is given. Refer to
for details of test standards.
Details of test methods and the conditions which apply for Type Approval testing in all
countries can be obtained from Tait Electronics Ltd.
The terms "wide bandwidth" and "narrow bandwidth" used in this and following sec-
tions are defined in the following table.
Wide Bandwidth
Narrow Bandwidth
1.2.2

General

Number Of Channels
Supply Voltage:
Operating Voltage
Standard Test Voltage
Polarity
Polarity Protection
Line Keying Supply (if required)
Supply Current:
Transmit
Standby
Operating Temperature Range
1. Additional channels may be factory programmed. Contact your nearest Tait Dealer or
Customer Service Organisation.
10/07/00
Channel Spacing
25kHz
12.5kHz
.. 128 (standard)
.. 10.8 to 16V DC
.. 13.8V DC
.. negative earth only
.. crowbar diode
.. -50V DC
.. 1.8A
.. 160mA
.. -30°C to +60°C
Modulation
100% Deviation
±5.0kHz
±2.5kHz
1
M880-00
Section 1.2.6
Receiver
IF Bandwidth
15.0kHz
7.5kHz
Copyright TEL

Advertisement

Table of Contents
loading

This manual is also suitable for:

T885T881