1.2

Specifications

1.2.1

Introduction

The performance figures given are minimum figures, unless otherwise indicated, for
equipment tuned with the maximum switching band and operating at standard room
temperature (+22°C to +28°C).
Where applicable, the test methods used to obtain the following performance figures are
those described in the EIA specification. However, there are several parameters for
which performance according to the CEPT specification is given.
Details of test methods and the conditions which apply for Type Approval testing in all
countries can be obtained from Tait Electronics Ltd.
1.2.2

General

Frequency Range
Type
Frequency Increment
Switching Range
Number Of Channels:
Standard
Optional .
Internally Selectable
Supply Voltage:
Operating Voltage
Standard Test Voltage
Polarity
Polarity Protection
Supply Current:
Standby
Full Audio
Input Impedance
Operating Temperature Range
Frequency Stability
(see also Section 1.3)
31/01/96
.. 136-174MHz
.. dual conversion superheterodyne
.. 5 or 6.25kHz
.. 3MHz
.. 1
.. 8
.. 128
.. 10.8 to 16V DC
.. 13.8V DC
.. negative earth only
.. crowbar diode
.. 350mA
.. 750mA
.. 50 ohms
.. -30°C to +60°C
.. ±2.5ppm, -30°C to +60°C