Battery Replacement; Additional Input Options - Badger Meter Blancett B2800 Programming Manual

Flow monitor
Hide thumbs Also See for Blancett B2800:
Table of Contents

Advertisement

Password
Password protection prevents unauthorized users from changing programming information Initially, the password is set to
all zeros To change the password, simply enter any four digit code using the arrow keys as previously described to enter the
password value Pressing ENTER once will store the password and take you back to the RST PSWD screen
N
OTEE:
This password will allow the operator to manually reset totals
Reset Password
The reset password screen allows the operator to enter any four digit code for the manual reset totals function
N
OTEE:
This reset password code will not allow the operator to enter PROGRAM mode
Reset Total
To reset the monitor total display, in RUN mode press MENU and ENTER simultaneously until TOTAL RST starts to flash TOTAL
RST will stop flashing and the display will return to the RUN mode at the conclusion of the reset procedure
Store Total
The current total can be manually stored in the monitor's flash memory This procedure may be desirable prior to replacing
the battery Press and hold ENTER for 2 seconds The display will respond with a flashing TOTALSVD and then return to the
RUN mode
Automatic Store Total
The monitor is equipped with a store total feature that works automatically, saving the current total to flash memory The
frequency of saves depends on the power supply option chosen
Battery Powered: Once per hour and just before a low battery condition turns the unit off
Loop Powered: Once every ten minutes

BATTERY REPLACEMENT

Battery powered monitors use a single 1 5V, "D" size, alkaline battery When replacement is necessary, use a clean fresh
battery to ensure continued trouble-free operation It is recommended that the total be saved to memory before the battery
is removed
Unscrew the two captive screws on the front panel to gain access to the battery Replace the battery, being sure to observe
the proper polarity, and then refasten the front panel

ADDITIONAL INPUT OPTIONS

The B2800 Flow monitor is capable of receiving magnetic pickup input (small signal sine wave) or a contact closure input
(pulse) Since most Blancett turbine flow meters utilize a magnetic pickup, the B2800 Flow monitor is shipped configured
for magnetic pickup input To change to a contact closure input, remove JP2 from the top two pins and jumper them to the
bottom two pins See
Figure 4
November 2013
Programming Manual
Page 9