You have completed the steps necessary for upgrading the IBM ServeRAID Cluster
Solution.

Installing the Microsoft Cluster Service software on Windows 2000

Installing the ServeRAID Manager program
Before installing MSCS, you must install the ServeRAID Manager program:
1. If the server is not running, turn on the server.
2. Log on to Windows 2000.
3. Insert the IBM ServeRAID Support CD (or the configuration CD that was
4. Click Next.
5. Click Yes to the Software License Agreement.
6. When prompted to select an operating system, select Windows NT/Windows
7. When prompted to install Windows NT Service, select Yes; then, click Next.
8. Select the Destination Folder; then, click Next.
9. After setup completes copying the files, click Finish.
Installing the Microsoft Cluster Service
To install the Microsoft Cluster Service, complete the following procedure:
114
®
IBM
User's Reference: ServeRAID
Important
Before beginning the procedure, consider the following:
v Ensure that you are using the IBM ServeRAID Device Drivers diskette (version 4.0 or
later) during the installation of Windows 2000 Advanced Server Edition or Windows 2000
Datacenter Server Edition.
v To create a ServeRAID cluster, you must install the Windows 2000 operating system on
an NTFS partition, and any shared cluster disks must be formatted as NTFS.
v While installing Windows 2000, do not install Microsoft Cluster Service. You will install
MSCS later.
v To install the ServeRAID device driver version 4.0 (or later), refer to "Installing device
drivers after installing Windows 2000" in the IBM ServeRAID-4 Ultra160 SCSI Controller
Device Driver Installation Guide.
included with your server) into the CD-ROM drive of Server A. The ServeRAID
Manager setup program starts.
2000; then, click Next.
1. Use the ServeRAID Manager program to scan for new drives on all ServeRAID
controllers.
2. On Server A, run the utility IPSHAHTO.EXE from the IBM ServeRAID Windows
NT Cluster Solutions Diskette or the IBM ServeRAID Support CD.
v If you are using the diskette, type the following command from a Windows
2000 command line:
a:\support\ipshahto
where a is the diskette drive letter.
v If you are using the CD, type the following command from a Windows 2000
command line:
d:\programs\winnt\cluster\support\ipshahto
where d is the CD-ROM drive letter.