Configuring the controller for Vinca High Availability for Novell
IntranetWare or Novell High Availability Server
If you are configuring ServeRAID controllers for Vinca High Availability for Novell
IntranetWare or Novell High Availability Server, following these steps:
10. Install the Vinca IntranetWare software on your servers. For installation

Configuring a controller for clustering

To configure a controller, do the following.
Note: For complete information on using the ServeRAID Manager program, refer to
1. Insert the IBM ServeRAID Support CD (or the configuration CD that was
100
®
IBM
User's Reference: ServeRAID
1. If necessary, perform any operating system shutdown procedure on both
servers that you are going to use in the cluster.
2. Turn off both servers.
3. If you have not done so, connect any shared external drive enclosures to both
servers; then, turn on the enclosures.
4. Follow the procedure "Configuring a controller for clustering" for each shared
controller in Server A.
5. Continue with the procedure "Configuring ServeRAID arrays and a logical
drive" on page 102 for Server A.
Note: In a typical Novell environment, create the logical drives on the server
that will maintain primary ownership of the disk resource. For example,
create one RAID level-5 logical drive on Server A and one RAID level-5
logical drive on Server B.
6. Follow the procedure "Configuring a controller for clustering" for each shared
controller in Server B.
7. Continue with the procedure "Configuring ServeRAID arrays and a logical
drive" on page 102 for Server B.
Note: If you define an online drive or hot-spare drive for Server A, you cannot
use that drive when creating arrays or hot-spare drives on Server B.
8. Restart Server A and Server B.
9. Install Novell NetWare on your servers. For installation information, refer to the
documentation that comes with your Novell NetWare software package.
information, refer to the documentation that comes with Vinca High Availability
for NetWare and IBM ServeRAID II SCSI Controller.
the ServeRAID Manager online help.
included with your server) into the CD-ROM drive; then, turn on the server. The
ServeRAID Manager program starts.
Note: If the ServeRAID Manager program opens in Configuration mode, a
window similar to the following opens. Click Cancel to go to Information
mode and go to the next step.
-4 Ultra160 SCSI Controller