IBM ServeRAID-4 Ultra160 Series User Reference page 163

Scsi controller
Hide thumbs Also See for ServeRAID-4 Ultra160 Series:
Table of Contents

Advertisement

BCS
ECS
Explanation
07
0C
Online/Rebuild drives are not responding, and a
drive was found at the incorrect SCSI ID.
07
1C
Online/Rebuild and Hot Spare/Standby
Hot-Spare drives are not responding, and a
drive was found at the incorrect SCSI ID.
07
2C
Online/Rebuild and Ready/Standby drives are
not responding, and a drive was found at the
incorrect SCSI ID.
07
3C
Online/Rebuild, Ready/Standby, and
Hot-Spare/Standby Hot-Spare drives are not
responding, and a drive was found at the
incorrect SCSI ID.
07
4C
Online/Rebuild drives are not responding, and a
drive was found at the incorrect SCSI ID, and
unidentified drives were found.
07
5C
Online/Rebuild and Hot Spare/Standby
Hot-Spare drives are not responding, a drive
was found at the incorrect SCSI ID, and
unidentified drives were found.
07
6C
Online/Rebuild and Ready/Standby drives are
not responding, a drive was found at the
incorrect SCSI ID, and unidentified drives were
found.
07
7C
Online/Rebuild, Ready/Standby, and
Hot-Spare/Standby Hot-Spare drives are not
responding, a drive was found at the incorrect
SCSI ID, and unidentified drives were found.
07
18
Online/Rebuild and Hot-Spare/Standby
Hot-Spare drives are not responding.
07
28
Online/Rebuild and Ready/Standby drives are
not responding.
07
38
Online/Rebuild, Ready/Standby, and
Hot-Spare/Standby Hot-Spare drives are not
responding.
07
48
Online/Rebuild drives are not responding, and
unidentified drives were found.
07
58
Online/Rebuild and Hot Spare/Standby
Hot-Spare drives are not responding, and
unidentified drives were found.
07
68
Online/Rebuild and Ready/Standby drives are
not responding, and unidentified drives were
found.
07
78
Online/Rebuild, Ready/Standby, and
Hot-Spare/Standby Hot-Spare drives are not
responding, and unidentified drives were found.
09
00
No error occurred.
Action
To correct the problem:
1. To keep the previous configuration in the
controller, replace the physical drives and cable
connections that were switched or moved; then,
press F4 to retry.
Note: Pressing F4 might not correct the
problem. If you do not return the drives and
cables to the previous configuration, the
message might return.
2. If all the physical drives are present and
connected correctly, one or more of the drives
might be faulty. Identify and replace the faulty
drives; then, press F5 to accept the changes.
3. To modify the configuration and accept the
rearrangement of the physical drives, press F6.
To exit without making changes, press F10.
To correct the problem:
1. To keep the previous configuration in the
controller, replace the physical drives and cable
connections that were switched or moved; then,
press F4 to retry.
2. If all the physical drives are present and
connected correctly, one or more of the drives
might be faulty. Identify and replace the faulty
drives; then, press F5 to accept the changes.
To exit without making changes, press F10.
No action is required. Press F10 to exit without
making any changes.
Chapter 18. Solving ServeRAID problems
145

Advertisement

Table of Contents
loading

Table of Contents