BTS3900(A) GSM
Commissioning Guide
----End
Issue 02 (2009-04-20)
(4) Click Configure Site Board Attributes tab. Then set Board Parameter
Configuration Enabled to Yes and set High Temperature Alarm Threshold
to 25.0, as shown in
Figure 4-29 Basic Attributes of Site Board (3)
(5) Click OK to complete the setting of the temperature alarm threshold.
3.
Check the alarm information of the DTCU. For details, see
Information of the BTS (on the
High Alarm, the ambient temperature alarm can be reported normally. If the alarm
cannot be reported normally, reconnect the related monitoring signal cables. For
details, see the Quick Installation Guide.
4.
Set High Temperature Alarm Threshold again to clear Temperature Too High
Alarm. For details, see
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4 Commissioning the BTS (Transmission Available)
Figure
4-29.
LMT). If the DTCU reports Temperature Too
Step
2.
4.4 Checking the Alarm
4-33