Figure 6-7 Site Device Panel Tab Page - Huawei BTS3900 GSM Commissioning Manual

Hide thumbs Also See for BTS3900 GSM:
Table of Contents

Advertisement

BTS3900(A) GSM
Commissioning Guide
Procedure
Step 1 In the navigation tree in the left pane of the BSC6000 Local Maintenance Terminal window,
select the BTS, and check whether the status of the three cascaded TRXs on the Site Device
Panel tab page is green, as shown in
l
l

Figure 6-7 Site Device Panel tab page

Step 2 If the status of the level 2 TRX and level 3 TRX is red, you can infer that the link between the
level 1 TRX and level 2 TRX is faulty. The system reports SFP Port Inconsistency Alarm.
Check whether the connection between the TRXs on the BTS side is normal, or clear the alarm
based on the BSS Alarm Reference.
Step 3 If the status of the level 3 TRX is red, you can infer that the link between the level 2 TRX and
level 3 TRX is faulty. The system reports SFP Port Inconsistency Alarm. Check the
Issue 02 (2009-04-20)
If the TRXs are displayed in green, you can infer that the TRXs are functional. End this
task.
If the TRXs are displayed in other colors, you can infer that the transmission between
cascaded TRXs is abnormal. Go to
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Figure
6-7.
Step
2.
6 Optional Commissioning Tasks
6-13