Page 1
Manual Index BARNES BARNES ® INSTALLATION MANUAL Submersible Sump & Sewage Ejectors Series: SE411HT .4Hp 1750 RPM, 60 Hz. IMPORTANT! Read all instructions in this manual before operating pump. As a result of Crane Pumps & Systems, Inc., constant product improvement program, product changes may occur.
PRESSURE GAUGE KIT (see parts list) Other brand and product names are trademarks or registered trademarks of their respective holders. ® Barnes is a registered trademark of Crane Pumps & Systems, Inc. 1999, 2000, 2002, 2003, 1/2006, 4/06, 9/06 Alteration Rights Reserved...
Manual Index SAFETY FIRST! Please Read This Before Installing Or Operating Pump. This information is provided for SAFETY and to PREVENT CAUTION ! Do not block or restrict discharge hose, as EQUIPMENT PROBLEMS. To help recognize this information, discharge hose may whip under pressure. observe the following symbols: IMPORTANT! Warns about hazards that can result WARNING ! Do not wear loose clothing that may...
B-4) Service Centers: C-3) Liquid Level Controls For the location of the nearest Barnes Service Center, check Figure 2 shows a typical installation for any submersible your Barnes representative or Crane Pumps & Systems, Inc., pump using a level control mounted to the discharge piping Service Department in Piqua, Ohio, telephone (937) 778-8947 with a piggy-back plug.
Page 6
Manual Index C-4) Electrical Connections: WARNING ! - Pump must be used in a circuit protected by a ground fault interrupter. WARNING ! - All model pumps and control panels must be properly grounded per THE NATIONAL ELECTRIC CODE or CANADIAN ELECTRIC CODE and STATE, PROVINCE and LOCAL electric codes.
Allow time for pump to cool sheets. These sheets are to be completed as applicable. to room temperature before handling or Return one copy to Barnes Pumps and store the second servicing. in the control panel or with the pump manual if no control panel is used.
Page 8
Manual Index F-1.2) Testing Oil: Pressure Gauge Assembly 10 PSI 1. Place pump on it’s side, remove pipe plug (24) and (See Parts List) drain oil into a clean, dry container. 2. Check oil for contamination using an oil tester with a Remove Pipe range to 30 kilovolts breakdown.
Page 9
Manual Index Inspect all parts for signs of wear and check motor FIGURE 6 resistance values. Check capacitor (7) with an Ohm meter by grounding the capacitor by placing a screwdriver across both terminals and then removing the screwdriver. Connect Ohm meter (set on high scale) to terminals, if needle moves to infi...
Manual Index Motor, Sleeve & Bearing Seal Pusher Spring Retaining Ring (3a) Rotating Member (3c) Bullet FIGURE 9 G-2 PART NUMBER: The part number consists of a six (6) digit number, which F-4.3) Replacing Exclusion Seal: appears in the catalog. A one or two letter suffi x may follow The exclusion seal (16), helps to keep debris away from the this number to designate the design confi...
Manual Index TROUBLE SHOOTING CAUTION ! Always disconnect the pump from the electrical power source before handling. If the system fails to operate properly, carefully read instructions and perform maintenance recommendations. If operating problems persist, the following chart may be of assistance in identifying and correcting them: MATCH “CAUSE”...
Manual Index IMPORTANT! WARRANTY REGISTRATION Your product is covered by the enclosed Warranty. Complete the Warranty Registration Form and return to Crane Pumps & Systems, Inc. Warranty Service Group If you have a claim under the provision of the warranty, contact your local Crane Pumps &...
Manual Index START-UP REPORT FOR SUBMERSIBLE PUMPS This form is designed to provide assurance that customer service and a quality product are the number one priority with Crane Pumps & Systems, Inc (CP&S). Please fi ll out the following questions as completely and accurate as possible. When complete, mail this form to: In U.S.A Send To: In Canada Send To:...
Page 18
Manual Index CP&S control panel part no. and brand Number of pumps operated by control panel NOTE: At no time should holes be made in top of control panel, unless proper sealing devices are utilized. Control panel manufactured by others Company name Model number Short circuit protection...
Manual Index IMPORTANT! WARRANTY REGISTRATION Your product is covered by the enclosed Warranty. Complete the Warranty Registration Form and return to Crane Pumps & Systems, Inc. Warranty Service Group If you have a claim under the provision of the warranty, contact your local Crane Pumps &...
Page 20
Manual Index FOLD HERE AND TAPE, DO NOT STAPLE PLACE STAMP HERE CRANE PUMPS & SYSTEMS, INC. WARRANTY SERVICE GROUP 420 THIRD STREET PIQUA, OHIO 45356 - U.S.A.