BARNES BARNES ® INSTALLATION and OPERATION MANUAL Submersible Sewage Ejector Series: 2SEV & 3SEV, L & DS .5, .75 & 1 HP, 1750 & 3450 RPM, 60 Hz. Single and Double Seal IMPORTANT! Read all instructions in this manual before operating pump.
PRESSURE GAUGE KIT (see parts list) Other brand and product names are trademarks or registered trademarks of their respective holders. ® Barnes is a registered trademark of Crane Pumps & Systems, Inc 1999, 2002, 11/03, 6/05, 4/06 , 9/06, 2/07...
SAFETY FIRST! Please Read This Before Installing Or Operating Pump. This information is provided for SAFETY and to PREVENT Do not block or restrict discharge hose, as discharge EQUIPMENT PROBLEMS. To help recognize this information, hose may whip under pressure. observe the following symbols: IMPORTANT! Warns about hazards that can result WARNING! - DO NOT wear loose clothing that may...
SECTION: A - PUMP SPECIFICATIONS: DISCHARGE ....2” NPT, Vertical, Bolt-on Flange SPEED ......1750 & 3450 RPM, 60Hz (nominal) 3” NPT, Vertical, Bolt-on Flange UPPER BEARING: LIQUID TEMPERATURE 104°F (40°C) Continuous Design ..Single Row, Ball, Oil Lubricated MOTOR HOUSING ..Cast Iron ASTM A-48, Class 30 Load .....
Page 5
2SEV-DS Series inches (mm) Plugs for 120 Volt and .5Hp, 240 Volt Single Phase Models. 3SEV-L Series Plugs for 120 Volt and .5Hp, 240 Volt Single Phase Models. 3SEV-DS Series Plugs for 120 Volt and .5Hp, 240 Volt Single Phase Models.
B-4) Service Centers: submersible wastewater pump to be installed or removed For the location of the nearest Barnes Service Center, check without requiring personnel to enter the wet well. Contact your your Barnes representative or Crane Pumps & Systems, Inc., local Barnes Pumps distributor for complete details.
Page 7
TYPICAL INSTALLATION WITH WIDE ANGLE LEVEL 120 Volt 1 Phase CONTROL Automatic Manual 240 Volt 1 Phase Automatic Manual FIGURE 2 FIGURE 3 Figure 2 shows a typical installation for 1 phase 120 and 240 volt pump with piggy-back plug for manual and automatic Automatic - Plug float cord into outlet, then plug pump operation.
MODEL PART HP VOLT/PH Hz RPM NEMA INSUL. FULL LOCKED CORD CORD CORD WINDING RESISTANCE (Nom) START CLASS LOAD ROTOR SIZE TYPE Emerson Franklin G.E. CODE AMPS AMPS inch (mm) Main-Start Main-Start Main-Start 2SEV514L 104918 120/1 60 1750 12.0 21.3 14/3 SJTOW 0.375 (9.5)
Page 9
MODEL PART VOLT/PH Hz RPM NEMA INSUL. FULL LOCKED CORD CORD CORD WINDING RESISTANCE (Nom) START CLASS LOAD ROTOR SIZE TYPE Emerson Franklin G.E. CODE AMPS AMPS inch (mm) Main-Start Main-Start Main-Start 104944 3SEV514L 120/1 1750 12.0 21.3 14/3 SJTOW 0.375 (9.5) 1.51-16.10 104945...
As the motor is oil filled, no lubrication or other maintenance AN OVERLOAD CONDITION OCCURS ! is required, and generally Barnes Pumps will give very reliable service and can be expected to operate for years on C-4.3) Moisture Sensors- DS Models: (Optional) normal sewage pumping without failing.
SECTION F: SERVICE AND REPAIR Pumps that have had the oil drained from the Motor Housing - Apply pipe sealant to pressure gauge assembly NOTE: All item numbers in ( ) refer to Figures 16 thru 19. and tighten into pipe plug hole (See Figure 3). Pressurize motor housing to 10 P.S.I.
Page 12
F-3.1) Disassembly and Inspection: TABLE 1 - COOLING OIL - Dielectric Outer Seal (All Units) - To expose shaft seal (28) for SUPPLIER GRADE examination, disassemble volute and impeller as outlined in Enerpar SE100 paragraph F-2.1. If further repair is required, remove retaining Conoco Pale Paraffin 22 ring (28d), spring (28c) and rotating member (28b) from shaft...
Page 13
Inner Seal (DS Units Only) - To expose inner shaft seal Motor & Seal Plate (28) for examination, remove outer seal as outlined above. Seal Pusher Remove socket head cap screws (64). Lift outer seal plate (29) and square-ring (27) from inner seal plate (5), See Figure 7. If further repair is required, remove snap ring (32), retaining ring (28d), spring (28c) and rotating member (28b) from shaft.
Page 14
(52) to connect wire assemblies (51) to sensor leads. If found to be defective, contact a motor service station or Barnes Pumps Service department. Bearings- When replacing bearing, be careful not to damage the rotor or shaft threads. Clean the shaft thoroughly. Press...
FIGURE 14 Reconnect motor and optional control leads to the underside G-2 PART NUMBER: of the terminal block(s) (21), (54 optional) as shown in Figure The part number consists of a six (6) digit number, which 14. Note that the pins are numbered underneath the terminal appears in the catalog.
TROUBLE SHOOTING CAUTION ! Always disconnect the pump from the electrical power source before handling. If the system fails to operate properly, carefully read instructions and perform maintenance recommendations. If operating problems persist, the following chart may be of assistance in identifying and correcting them: MATCH “CAUSE”...
IMPORTANT! WARRANTY REGISTRATION IMPORTANT! WARRANTY REGISTRATION Your product is covered by a warranty: Your product is covered by the enclosed Warranty. www.cranepumps.com/downloadables/CATALOGS_OIPMs/Warranty/24MonthWarranty.pdf If you have a claim under the provisions of the warranty, contact your local If you have a claim under the provision of the warranty, contact your local Crane Pumps &...