2.4

Initial setting for Ethernet communication

Use the following parameters to perform required settings for Ethernet communication between the inverter and other devices.
To make communication between other devices and the inverter, perform the initial settings of the inverter parameters to match
the communication specifications of the devices. Data communication cannot be made if the initial settings are not made or if
there is any setting error.
Pr.
Name
1434
IP address 1 (Ethernet)
*1
N600
1435
IP address 2 (Ethernet)
*1
N601
1436
IP address 3 (Ethernet)
*1
N602
1437
IP address 4 (Ethernet)
*1
N603
*1
The setting is applied after an inverter reset or next power-ON.
 IP address (Pr.1434 to Pr.1437)
Enter the IP address of the inverter to be connected to Ethernet in Pr.1434 to Pr.1437. (Enter the IP address assigned by the
network administrator.)
* * * . * * * . * * * . * * *
Initial
Setting
value
range
192
168
0 to 255
50
1
Set the value in the first octet in Pr.1434.
Set the value in the second octet in Pr.1435.
Set the value in the third octet in Pr.1436.
Set the value in the fourth octet in Pr.1437.
Description
Enter the IP address of the inverter to be connected to Ethernet.