Mitsubishi Electric FR-E800 Instruction Manual (Communication page 164

Hide thumbs Also See for FR-E800:
Table of Contents

Advertisement

• Gateway (P61003)
PNU
Sub
Access
0
1
61003
R
2
3
• Subnet mask (P61004)
PNU
Sub
Access
0
1
61004
R
2
3
 PROFIdrive parameter request format (master to slave)
Byte No.
0
1
Header
2
3
4
5
Parameter
address
6
7
8
9
10
11
Parameter value
12
13
14 to 237
238
239
*1
Availability depends on the format or data size.
 PROFIdrive parameter response format (slave to master)
Byte No.
0
Request reference
1
Request ID
Header
2
DO-ID
Number of
3
parameters
Name
Gateway
Octetstring4
Name
Subnet mask
Octetstring4
Field
Request reference
Request ID
DO-ID
Number of parameters
Attribute
Number of elements (n)
PNU number
Sub-index
Format
Number of data
Parameter value
Field
Description
Determined by the setting in the
master
Parameter read (positive): 01h
Parameter change (positive): 02h
Parameter read (negative): 81h
Parameter change (negative): 82h
Request ID fault: 80h
01h
01h
Data Type
Description
Gateway address first octet
Gateway address second octet
Gateway address third octet
Gateway address fourth octet
Data Type
Description
Subnet mask first octet
Subnet mask second octet
Subnet mask third octet
Subnet mask fourth octet
Description
Determined by the setting in the master
Parameter read: 01h
Parameter change: 02h
01h
01h
10h
Determined by the number of arrays (234
max.)
0 or 1 for data types other than array or
octetstring
Refer to
page
158.
Data Type
Unsigned16: 06h
Octetstring: 0Ah
V2: 73h
Number of arrays
Parameter writing value
Parameter read
Positive
Default
Default
255
255
255
0
Parameter
Parameter
read
change
×
×
×
×
*1
×
*1
×
*1
×
Parameter change
Negative
Positive
Negative
2. Ethernet Communication
2.12 PROFINET
1
2
3
4
5
6
7
8
9
10
163