Mitsubishi Electric FR-E800 Instruction Manual (Communication page 74

Hide thumbs Also See for FR-E800:
Table of Contents

Advertisement

• System configuration example (when the MELSEC iQ-R series programmable controller is used)
Programmable
controller
• Setting network parameters of the master station
In the programming example, network parameters are set as follows.
Item
Station type
Start I/O
Quantity
Remote input (RX)
Remote output (RY)
Remote register (RWr)
Remote register (RWw)
Retry count
 Schematic diagrams of remote I/O and remote register devices
• The following diagram shows the remote I/O (RX and RY) transmitted between the programmable controller CPU and
remote device stations. Shaded areas show the devices actually used.
Power
CPU
supply
R04CPU
R61P
Hub
Inverter
(station
No.1)
Setting condition
CC-Link IE Field Network Basic (master station)
0000
2
X1000
Y1000
W0
W100
3
Programmable controller CPU
X100F to X1000
X101F to X1010
X102F to X1020
X103F to X1030
X104F to X1040
X105F to X1050
Y100F to Y1000
Y101F to Y1010
Y102F to Y1020
Y103F to Y1030
Y104F to Y1040
Y105F to Y1050
Input module
Output module
RX40C7
RY40PT5P
(X20 to X2F)
(Y30 to Y3F)
Inverter
Pr.544=0
Pr.544=0
(station
No.2)
Remote device station
(station 1)
RX0F to RX00
RX1F to RX10
RY0F to RY00
RY1F to RY10
Remote device station
(station 2)
RX0F to RX00
RX1F to RX10
RY0F to RY00
RY1F to RY10
2. Ethernet Communication
2.6 CC-Link IE Field Network Basic
1
2
3
4
5
6
7
8
9
10
73