[Values to be printed 1]
0 to 255 times
[Description 2] Timeout for tag read retry
[Values to be printed 2]
0 to 9.9 sec.
WRITE RETRY [ ]
[Description 1] The number of times tag write is retried
[Values to be printed 1]
0 to 255 times
[Description 2] Timeout for tag write retry
[Values to be printed 2]
0 to 9.9 sec.
POWER LEVEL [ ]
[Description] Radio output level
[Values to be printed] B-EX6T1/T3
0 to 18: B-EX706-RFID-U4-EU/US/AU-R, B-EX706-RFID-U4-R
[Values to be printed] B-EX4T1
9 to 18: B-EX700-RFID-U2-US/EU-R
0 to 18: B-EX700-RFID-U4-EU/US/AU-R, B-EX700-RFID-U4-R, U4 module preinstall model
Q VALUE [ ]
[Description] RFID module Q value
[Values to be printed]
0 to 15
AGC THRESHOLD [ ]
[Description] AGC threshold setting
[Values to be printed]
0 to 15
WRITE AGC [ ]
[Description] AGC threshold for data write
[Values to be printed]
0 to 15
RETRY MIN AGC [ ]
[Description] AGC threshold lower limit for retry
[Values to be printed]
0 to 15
TAG CHECK [1] [2] [3]
[Description 1] Error tag detection
[Values to be printed 1]
OFF:
Error tag detection is not performed.
EPCCODE:
Error tag detection is performed. ID area data is read before data write to check for error.
PASSWORD: Error tag detection is performed. Access password area is read before data write to
check for error.
Note: This value is valid only for GEN2 tags.
[Description 2] Password setting to protect error tag detection
Note: Only when "ON (ACCESS PASSWORD)" is selected for TAG CHECK
[Values to be printed 2]
OFF:
Disabled.
ON:
Enabled.