3. Operating Procedures
• The clock is not oscillating correctly.
Consider the following possible causes if transfer is not possible even though the PLL_Locked pin (Port13)
has switched to High.
• The CLKSEL pin setting does not match the clock frequency.
• The RS-232 cable (cross/straight) used is incorrect for the circuit board wiring.
• The terminal software settings differ from those described in Table 2-1.
3.1

Key Input Specifications

The key input specifications are as follows:
• The Enter key confirms the string entered.
• Only single-byte alphanumeric characters can be entered. Double-byte characters are invalid.
• Input is not case-sensitive.
3.2

Main Menu

Start these functions by entering "menu" via the PC terminal software. This will display the items
shown in Table 3-1.
Key Input
1

USB analog test

2

Diagnostic

q

Quit

3.2.1
USB Analog Test
When key input "1" is received, then the operation menu is displayed and to allow
switching to Test mode. For detailed information, refer to S1R72U16 Embedded Host
Compliance Guide.
3.2.2
Diagnostic
When key input "2" is received, then the operation menu is displayed and to start the
history display function. For detailed information, refer to "3.3 History Display Function
Menu".
3.2.3
Quit
When key input "q" is received, then this quits the function. The function will be
unavailable until the "menu" is invoked once again.
4
Table 3-1 Main menu list
Item
Allows switching to Test mode.
Starts the history display function.
Quits the function.
EPSON
Summary
S1R72U16 Development Support
Manual (Rev.2.00)